Your browser doesn't support javascript.
loading
Evaluation of RealStar Reverse Transcription-Polymerase Chain Reaction Kits for Filovirus Detection in the Laboratory and Field.
Rieger, Toni; Kerber, Romy; El Halas, Hussein; Pallasch, Elisa; Duraffour, Sophie; Günther, Stephan; Ölschläger, Stephan.
Afiliação
  • Rieger T; Department of Virology, Bernhard Nocht Institute for Tropical Medicine.
  • Kerber R; Department of Virology, Bernhard Nocht Institute for Tropical Medicine.
  • El Halas H; altona Diagnostics.
  • Pallasch E; Department of Virology, Bernhard Nocht Institute for Tropical Medicine German Center for Infection Research, Hamburg, Germany.
  • Duraffour S; Department of Virology, Bernhard Nocht Institute for Tropical Medicine.
  • Günther S; Department of Virology, Bernhard Nocht Institute for Tropical Medicine German Center for Infection Research, Hamburg, Germany.
  • Ölschläger S; altona Diagnostics.
J Infect Dis ; 214(suppl 3): S243-S249, 2016 10 15.
Article em En | MEDLINE | ID: mdl-27549586
ABSTRACT

BACKGROUND:

Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing.

METHODS:

The RealStar Filovirus Screen reverse transcription-polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD.

RESULTS:

The Filovirus Screen kit detected EBOV, Sudan virus, Taï Forest virus, Bundibugyo virus, Reston virus, and Marburg virus and differentiated between the genera Ebolavirus and Marburgvirus The amount of filovirus RNA that could be detected with a probability of 95% ranged from 11 to 67 RNA copies/reaction on a LightCycler 480 II. The Zaire Ebolavirus kit is based on the Filovirus Screen kit but was optimized for detection of EBOV. It has an improved signal-to-noise ratio at low EBOV RNA concentrations and is somewhat more sensitive than the Filovirus kit. Both kits show significantly lower analytical sensitivity on a SmartCycler II. Clinical evaluation revealed that the SmartCycler II, compared with other real-time PCR platforms, decreases the clinical sensitivity of the Filovirus Screen kit to diagnose EVD at an early stage.

CONCLUSIONS:

The Filovirus Screen kit detects all human-pathogenic filoviruses with good analytical sensitivity if performed on an appropriate real-time PCR platform. High analytical sensitivity is important for early diagnosis of EVD.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Filoviridae / Infecções por Filoviridae / Doença pelo Vírus Ebola / Reação em Cadeia da Polimerase Via Transcriptase Reversa / Ebolavirus Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Filoviridae / Infecções por Filoviridae / Doença pelo Vírus Ebola / Reação em Cadeia da Polimerase Via Transcriptase Reversa / Ebolavirus Idioma: En Ano de publicação: 2016 Tipo de documento: Article