Your browser doesn't support javascript.
loading
Computed tomography for the detection of distal radioulnar joint instability: normal variation and reliability of four CT scoring systems in 46 patients.
Wijffels, Mathieu; Stomp, Wouter; Krijnen, Pieta; Reijnierse, Monique; Schipper, Inger.
Afiliação
  • Wijffels M; Department of Surgery-Trauma Surgery, Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, The Netherlands. mmewijffels@hotmail.com.
  • Stomp W; Department of Radiology, Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, The Netherlands.
  • Krijnen P; Department of Surgery-Trauma Surgery, Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, The Netherlands.
  • Reijnierse M; Department of Radiology, Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, The Netherlands.
  • Schipper I; Department of Surgery-Trauma Surgery, Leiden University Medical Center, P.O. Box 9600, 2300 RC, Leiden, The Netherlands.
Skeletal Radiol ; 45(11): 1487-93, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27554667
ABSTRACT

OBJECTIVES:

The diagnosis of distal radioulnar joint (DRUJ) instability is clinically challenging. Computed tomography (CT) may aid in the diagnosis, but the reliability and normal variation for DRUJ translation on CT have not been established in detail. The aim of this study was to evaluate inter- and intraobserver agreement and normal ranges of CT scoring methods for determination of DRUJ translation in both posttraumatic and uninjured wrists. MATERIALS AND

METHODS:

Patients with a conservatively treated, unilateral distal radius fracture were included. CT scans of both wrists were evaluated independently, by two readers using the radioulnar line method, subluxation ratio method, epicenter method and radioulnar ratio method. The inter- and intraobserver agreement was assessed and normal values were determined based on the uninjured wrists.

RESULTS:

Ninety-two wrist CTs (mean age 56.5 years, SD 17.0, mean follow-up 4.2 years, SD 0.5) were evaluated. Interobserver agreement was best for the epicenter method [ICC = 0.73, 95 % confidence interval (CI) 0.65-0.79]. Intraobserver agreement was almost perfect for the radioulnar line method (ICC = 0.82, 95 % CI 0.77-0.87). Each method showed a wide normal range for normal DRUJ translation. Normal range for the epicenter method is -0.35 to -0.06 in pronation and -0.11 to 0.19 in supination.

CONCLUSION:

DRUJ translation on CT in pro- and supination can be reliably evaluated in both normal and posttraumatic wrists, however with large normal variation. The epicenter method seems the most reliable. Scanning of both wrists might be helpful to prevent the radiological overdiagnosis of instability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Fraturas do Rádio / Ulna / Traumatismos do Punho / Articulação do Punho / Tomografia Computadorizada por Raios X / Instabilidade Articular Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Fraturas do Rádio / Ulna / Traumatismos do Punho / Articulação do Punho / Tomografia Computadorizada por Raios X / Instabilidade Articular Idioma: En Ano de publicação: 2016 Tipo de documento: Article