Influence of Surface Treatments and Adhesive Systems on Lithium Disilicate Microshear Bond Strength.
Garboza, Celso Sebastião; Berger, Sandrine Bittencourt; Guiraldo, Ricardo Danil; Fugolin, Ana Paula Piovezan; Gonini-Júnior, Alcides; Moura, Sandra Kiss; Lopes, Murilo Baena.
Afiliação
  • Garboza CS; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
  • Berger SB; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
  • Guiraldo RD; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
  • Fugolin AP; Department of Restorative Dentistry, Piracicaba Dental School, UNICAMP - Universidade Estadual de Campinas, Piracicaba, SP, Brazil.
  • Gonini-Júnior A; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
  • Moura SK; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
  • Lopes MB; Department of Restorative Dentistry, School of Dentistry, UNOPAR - Universidade Norte do Paraná, Londrina, PR, Brazil.
Braz Dent J ; 27(4): 458-62, 2016.
Article em En | MEDLINE | ID: mdl-27652711
ABSTRACT
The purpose of this study was to evaluate the microshear bond strength of ceramic prosthetic structures reinforced by lithium disilicate cemented with resin cement under conditions of different surface treatments and adhesive systems. Seventy-two rectangular blocks of lithium disilicate (6.5 mm long × 5 mm wide × 1 mm thick) were fabricated, air abraded with 50-µm Al2O3 particles and divided into six groups (n=12) depending on the surface pretreatments. The groups were as follows 10HF/S/SBM 10% hydrofluoric acid etched for 20 s (10HF) + silane (S) + Adper Scotchbond Multi-Purpose (SBM); 10HF/S/SB 10HF + S + Single Bond Universal (SB); 10HF/SBM; 10HF/SB; S/SBM and S/SB. Two 1-mm-long plastic tubes were placed on the specimens, filled with RelyX ARC resin cement and cured for 20 s per tube. The plastic tube was removed, and the microshear bond strength was tested. Data were submitted to analysis of variance and Tukey's tests (α=0.05). Fractured specimens were observed under optical microscopy. For both adhesives, the bond strengths (MPa) of groups treated with acid-etching and silane (10HF/S/SB 24.82, 10HF/S/SBM 24.90) were higher (p<0.001) than those of groups treated with acid-etching (10HF/SB 16.47, 10HF/SBM 19.94) only or only silane (S/SB 18.42, S/SBM 13.24). All groups showed a predominance of failure adhesive. The silanization should be a clinical step in cementing ceramic structures reinforced by lithium disilicate, even with the application of universal adhesive that contains silane in its formulation.