Your browser doesn't support javascript.
loading
The second gamma-H2AX assay inter-comparison exercise carried out in the framework of the European biodosimetry network (RENEB).
Moquet, Jayne; Barnard, Stephen; Staynova, Albena; Lindholm, Carita; Monteiro Gil, Octávia; Martins, Vanda; Rößler, Ute; Vral, Anne; Vandevoorde, Charlot; Wojewódzka, Maria; Rothkamm, Kai.
Afiliação
  • Moquet J; a Public Health England, Centre for Radiation Chemical and Environmental Hazards , Chilton , UK.
  • Barnard S; a Public Health England, Centre for Radiation Chemical and Environmental Hazards , Chilton , UK.
  • Staynova A; b National Centre of Radiobiology and Radiation Protection , Sofia , Bulgaria.
  • Lindholm C; c Radiation and Nuclear Safety Authority (STUK) , Helsinki , Finland.
  • Monteiro Gil O; d Instituto Superior Técnico, Universidade de Lisboa, C2TN, Bobadela-LRS , Portugal.
  • Martins V; d Instituto Superior Técnico, Universidade de Lisboa, C2TN, Bobadela-LRS , Portugal.
  • Rößler U; e Bundesamt für Strahlenschutz , Oberschleissheim , Germany.
  • Vral A; f Department of Basic Medical Sciences , Ghent University , Ghent , Belgium.
  • Vandevoorde C; f Department of Basic Medical Sciences , Ghent University , Ghent , Belgium.
  • Wojewódzka M; g Themba LABS, National Research Foundation , Somerset West , South Africa.
  • Rothkamm K; h Institute of Nuclear Chemistry and Technology, Centre for Radiobiology and Biological Dosimetry , Warsaw , Poland.
Int J Radiat Biol ; 93(1): 58-64, 2017 01.
Article em En | MEDLINE | ID: mdl-27686523
PURPOSE: Within the EU RENEB project, seven laboratories have taken part in training and harmonisation activities to strengthen triage gamma-H2AX-based radiation exposure assessment. This has culminated in a second triage biodosimetry exercise. MATERIALS AND METHODS: Whole blood and separated lymphocyte samples were homogenously irradiated with 60Co gamma rays at 0.5, 2.5 (blind samples), 0 and 2 Gy (reference samples). Following post-exposure incubations of 4 and 24 h, 16 samples were shipped on ice packs to each partner. The samples were stained and scored for gamma-H2AX foci, using manual and/or automated fluorescence microscope scoring strategies. Dose estimates were obtained and used to assign triage categories to the samples. RESULTS: Average dose estimates across all the laboratories correlated well with true doses. The most accurate assignment of triage category was achieved by manual scoring of the 4-h blood and lymphocyte samples. Only three samples out of a total of 46 were miscategorized in a way that could have adversely effected the clinical management of a radiation casualty. CONCLUSIONS: This inter-comparison exercise has demonstrated that following a recent acute radiation exposure, the gamma-H2AX assay could be a useful triage tool that can be successfully applied across a network of laboratories.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bioensaio / Dano ao DNA / Monitoramento de Radiação / Aberrações Cromossômicas / Exposição à Radiação / Raios gama Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bioensaio / Dano ao DNA / Monitoramento de Radiação / Aberrações Cromossômicas / Exposição à Radiação / Raios gama Idioma: En Ano de publicação: 2017 Tipo de documento: Article