Your browser doesn't support javascript.
loading
TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve.
Barnhart, Glenn R; Accola, Kevin D; Grossi, Eugene A; Woo, Y Joseph; Mumtaz, Mubashir A; Sabik, Joseph F; Slachman, Frank N; Patel, Himanshu J; Borger, Michael A; Garrett, H Edward; Rodriguez, Evelio; McCarthy, Patrick M; Ryan, William H; Duhay, Francis G; Mack, Michael J; Chitwood, W Randolph.
Afiliação
  • Barnhart GR; Swedish Heart and Vascular Institute, Structural Heart Program, Seattle, Wash. Electronic address: Glenn.Barnhart@swedish.org.
  • Accola KD; Florida Hospital Cardiovascular Institute, Florida Hospital Orlando, Orlando, Fla.
  • Grossi EA; Department of Cardiothoracic Surgery, New York University School of Medicine, New York, NY.
  • Woo YJ; Department of Cardiothoracic Surgery, Stanford University, Palo Alto, Calif.
  • Mumtaz MA; Cardiovascular & Thoracic Surgery, Pinnacle Health, Harrisburg, Pa.
  • Sabik JF; Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic Foundation, Cleveland, Ohio.
  • Slachman FN; Mercy Medical Group, Mercy General Hospital, Sacramento, Calif.
  • Patel HJ; Cardiac Surgery Department, University of Michigan, Ann Arbor, Mich.
  • Borger MA; Department of Surgery, Columbia University Medical Center, New York, NY.
  • Garrett HE; Cardiovascular Surgery Clinic, Baptist Memorial Hospital, Memphis, Tenn.
  • Rodriguez E; Saint Thomas Heart Program, Saint Thomas Heart Hospital, Nashville, Tenn.
  • McCarthy PM; Division of Cardiac Surgery, Northwestern Memorial Hospital, Chicago, Ill.
  • Ryan WH; Cardiac Surgery Specialists, Baylor Plano Heart Hospital, Plano, Tex.
  • Duhay FG; Edwards Lifesciences LLC, Irvine, Calif.
  • Mack MJ; Cardiac Surgery Specialists, Baylor Plano Heart Hospital, Plano, Tex.
  • Chitwood WR; Department of Cardiovascular Sciences, East Carolina University, Greenville, NC.
J Thorac Cardiovasc Surg ; 153(2): 241-251.e2, 2017 02.
Article em En | MEDLINE | ID: mdl-27817951
BACKGROUND: The TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) trial (NCT01700439) evaluated the performance of the INTUITY rapid deployment aortic valve replacement (RDAVR) system in patients with severe aortic stenosis. METHODS: TRANSFORM was a prospective, nonrandomized, multicenter (n = 29), single-arm trial. INTUITY is comprised of a cloth-covered balloon-expandable frame attached to a Carpentier-Edwards PERIMOUNT Magna Ease aortic valve. Primary and effectiveness endpoints were evaluated at 1 year. RESULTS: Between 2012 and 2015, 839 patients underwent RDAVR. Mean age was 73.5 ± 8.3 years. Full sternotomy (FS) was used in 59% and minimally invasive surgical incisions in 41%. Technical success rate was 95%. For isolated RDAVR, mean crossclamp and cardiopulmonary bypass times for FS were 49.3 ± 26.9 minutes and 69.2 ± 34.7 minutes, respectively, and for minimally invasive surgical 63.1 ± 25.4 minutes and 84.6 ± 33.5 minutes, respectively. These times were favorable compared with Society of Thoracic Surgeons database comparators for FS: 76.3 minutes and 104.2 minutes, respectively, and for minimally invasive surgical, 82.9 minutes and 111.4 minutes, respectively (P < .001). At 30 days, all-cause mortality was 0.8%; valve explant, 0.1%; thromboembolism, 3.5%; and major bleeding, 1.3%. In patients with isolated aortic valve replacement, the rate of permanent pacemaker implantation was 11.9%. At 1 year, mean effective orifice area was 1.7 cm2; mean gradient, 10.3 mm Hg; and moderate and severe paravalvular leak, 1.2% and 0.4%, respectively. CONCLUSIONS: INTUITY RDAVR performed effectively in this North American trial. It may lead to a relative reduction in aortic crossclamp time and cardiopulmonary bypass time and has excellent hemodynamic performance. Pacemaker implantation rate observed was somewhat greater than European trials and requires further investigation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Desenho de Prótese / Próteses Valvulares Cardíacas / Procedimentos Cirúrgicos Minimamente Invasivos / Implante de Prótese de Valva Cardíaca / Procedimentos Cirúrgicos sem Sutura Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Desenho de Prótese / Próteses Valvulares Cardíacas / Procedimentos Cirúrgicos Minimamente Invasivos / Implante de Prótese de Valva Cardíaca / Procedimentos Cirúrgicos sem Sutura Idioma: En Ano de publicação: 2017 Tipo de documento: Article