Your browser doesn't support javascript.
loading
Quarterly Reporting of Computed Tomography Ordering History Reduces the Use of Imaging in an Emergency Department.
Ehrlichman, Richard; Dezman, Zachary; Klein, Joel; Jeudy, Jean; Lemkin, Daniel.
Afiliação
  • Ehrlichman R; Department of Emergency Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
  • Dezman Z; Department of Emergency Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
  • Klein J; Baltimore-Washington Hospital Center, University of Maryland, Baltimore, Maryland.
  • Jeudy J; Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
  • Lemkin D; Department of Emergency Medicine, University of Maryland School of Medicine, Baltimore, Maryland.
J Emerg Med ; 52(5): 684-689, 2017 May.
Article em En | MEDLINE | ID: mdl-27955985
ABSTRACT

BACKGROUND:

Computed tomography (CT) is a useful and necessary part of many emergency department (ED) assessments. However, the costs of imaging and the health risks associated with radiation exposure have sparked national efforts to reduce CT ordering in EDs. STUDY

OBJECTIVE:

We analyzed CT ordering habits prior to and following implementation of a feedback tool at a community hospital.

METHODS:

In this intervention study, we identified the CT-ordering habits of physicians and mid-level care providers (physician assistants and nurse practitioners) at baseline and after implementation of a system that sent quarterly feedback reports comparing their ordering habits with those of their peers. Variability in ordering and subgroup analyses by body region were included in these reports.

RESULTS:

We examined the records of 104,454 patients seen between October 1, 2013 and December 31, 2014. There were 5552 or 21.0% of patients seen during the baseline period that underwent CT imaging. We observed an absolute reduction in imaging of 2.3% (95% confidence interval 1.7-2.8%) after implementation, avoiding approximately $400,000 in costs, 22 days of scanning time, and radiation exposure equivalent to 33,000 chest films annually. These changes occurred across physicians and mid-level providers, regardless of the number years of practice or board certification.

CONCLUSIONS:

Implementation of a feedback mechanism reduced CT use by emergency medicine practitioners, with concomitant reductions in cost and radiation exposure. The change was similar across levels of medical care. Future studies will examine the effect of the feedback reporting system at other institutions in our hospital network.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Padrões de Prática Médica / Tomografia Computadorizada por Raios X / Revisão da Utilização de Recursos de Saúde / Estudos de Avaliação como Assunto Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Padrões de Prática Médica / Tomografia Computadorizada por Raios X / Revisão da Utilização de Recursos de Saúde / Estudos de Avaliação como Assunto Idioma: En Ano de publicação: 2017 Tipo de documento: Article