Your browser doesn't support javascript.
loading
Microstructure, surface characterization and long-term stability of new quaternary Ti-Zr-Ta-Ag alloy for implant use.
Vasilescu, C; Osiceanu, P; Moreno, J M Calderon; Drob, S I; Preda, S; Popa, M; Dan, I; Marcu, M; Prodana, M; Popovici, I A; Ionita, D; Vasilescu, E.
Afiliação
  • Vasilescu C; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Osiceanu P; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Moreno JMC; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Drob SI; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania. Electronic address: sidrob.icf@gmail.com.
  • Preda S; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Popa M; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Dan I; Research and Development SRL, Bucharest, Romania.
  • Marcu M; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
  • Prodana M; Department of General Chemistry, Faculty of Applied Chemistry and Materials Science, Bucharest, Romania.
  • Popovici IA; University of Medicine and Pharmacy "Carol Davila", Bucharest, Romania.
  • Ionita D; Department of General Chemistry, Faculty of Applied Chemistry and Materials Science, Bucharest, Romania.
  • Vasilescu E; Institute of Physical Chemistry "Ilie Murgulescu", Bucharest, Romania.
Mater Sci Eng C Mater Biol Appl ; 71: 322-334, 2017 Feb 01.
Article em En | MEDLINE | ID: mdl-27987714
The novel Ti-20Zr-5Ta-2Ag alloy was characterised concerning its microstructure, morphology, mechanical properties, its passive film composition and thickness, its long-term electrochemical stability, corrosion resistance, ion release rate in Ringer solution of acid, neutral and alkaline pH values and antibacterial activity. The new alloy has a crystalline α microstructure (by XRD). Long-term XPS and SEM analyses show the thickening of the passive film and the deposition of hydroxyapatite in neutral and alkaline Ringer solution. The values of the electrochemical parameters confirm the over time stability of the new alloy passive film. All corrosion parameters have very favourable values in time which attest a high resistance to corrosion. Impedance spectra evinced a bi-layered passive film formed by the barrier, insulating layer and the porous layer. The monitoring of the open circuit potentials indicated the stability of the protective layers and their thickening in time. The new alloy releases (by ICP-MS measurements) very low quantities of Ti, Zr, Ag ions and no Ta ions. The new alloy exhibits a low antibacterial activity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Titânio / Zircônio / Implantes Experimentais / Ligas / Antibacterianos Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prata / Titânio / Zircônio / Implantes Experimentais / Ligas / Antibacterianos Idioma: En Ano de publicação: 2017 Tipo de documento: Article