Your browser doesn't support javascript.
loading
Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans: A comparative in vitro study.
Shamseddine, Loubna; Mortada, Rola; Rifai, Khaldoun; Chidiac, Jose Johann.
Afiliação
  • Shamseddine L; Assistant Professor, Prosthodontics Department, Lebanese University School of Dentistry, Beirut, Lebanon. Electronic address: drloubna1@hotmail.com.
  • Mortada R; Clinical instructor, Prosthodontics Department, Lebanese University School of Dentistry, Beirut, Lebanon.
  • Rifai K; Professor, Prosthodontics Department, Lebanese University School of Dentistry, Beirut, Lebanon.
  • Chidiac JJ; Professor, Prosthodontics Department, Lebanese University School of Dentistry, Beirut, Lebanon.
J Prosthet Dent ; 118(1): 49-54, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28024815
ABSTRACT
STATEMENT OF

PROBLEM:

Subtractive and additive computer-aided design and computer-aided manufacturing (CAD-CAM) wax pattern processing are 2 methods of fabricating a pressed ceramic crown. Whether a subtractive milled wax pattern or a pattern from the micro-stereolithography additive process produces lithium disilicate crowns with better marginal and internal fit is unclear. MATERIALS AND

METHODS:

Ten silicone impressions were made for a prepared canine tooth. Each die received 2 lithium disilicate (IPS e.max) copings, 1 from milled wax blocks and 1 from additive wax. The replica technique was used to measure the fit by scanning electron microscopy at ×80 magnification. Collected data were analyzed using the paired Student t test for the marginal and internal fit. For the occlusal fit, the difference in scores did not follow a normal distribution, and the Wilcoxon signed rank test was used (α=.05).

RESULTS:

The mean marginal, axial, and occlusal fit showed no significant differences when the 2 CAD-CAM manufacturing processes were compared (P>.05). For the marginal fit, the mean (±SD) values were 105.1 µm ±39.6 with the milled process and 126.2 µm ±25.2 for the additive process. The mean values were 98.1 µm ±26.1 for the axial fit in the milled process and 106.8 µm ±21.2 in the additive process. For the occlusal fit, median values (interquartile interval) were 199.0 µm (141.5 to 269.9) for subtractive manufacturing and 257.2 µm (171.6 to 266.0) for micro-SLA manufacturing.

CONCLUSIONS:

No significant difference was found between the fit of the 2 techniques. The mean values of axial and occlusal median values were 10 and 5 to 6 times greater than machine's nominal values.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador / Adaptação Marginal Dentária / Coroas Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador / Adaptação Marginal Dentária / Coroas Idioma: En Ano de publicação: 2017 Tipo de documento: Article