Your browser doesn't support javascript.
loading
Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers.
Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J; Hsieh, K-C.
Afiliação
  • Cheng MF; Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan; Division of Histology and Clinical Pathology, Hualien Armed Forced General Hospital, Hualien, Taiwan; Institute of Oral Biology, School of Dentistry, National Yang-Ming University, Taipei, Taiwan;
  • Chen YY; Department of Combat Sports, National Taiwan University of Physical Education and Sport, Taichung, Taiwan; These authors contributed equally.
  • Jang TR; Department of Physical Education, National Taiwan University of Physical Education and Sport, Taichung, Taiwan.
  • Lin WL; Department of Sport Management, National Taiwan University of Physical Education and Sport, Taichung, Taiwan.
  • Chen J; Department of laboratory medicine, Hualian Armed Forces General Hospital, Hualian, Taiwan.
  • Hsieh KC; Office of Physical Education and Sport, National Chung Hsing University, Taichung, Taiwan.
Biol Sport ; 33(4): 399-405, 2016 Dec.
Article em En | MEDLINE | ID: mdl-28090145
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA8, Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht2/Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article