Your browser doesn't support javascript.
loading
Imaging-Concordant Benign MRI-Guided Vacuum-Assisted Breast Biopsy May Not Warrant MRI Follow-Up.
Huang, Monica L; Speer, Megan; Dogan, Basak E; Rauch, Gaiane M; Candelaria, Rosalind P; Adrada, Beatriz E; Hess, Kenneth R; Yang, Wei T.
Afiliação
  • Huang ML; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
  • Speer M; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
  • Dogan BE; 2 Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX.
  • Rauch GM; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
  • Candelaria RP; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
  • Adrada BE; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
  • Hess KR; 3 Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Yang WT; 1 Department of Diagnostic Radiology, Section of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Unit 1350, Houston, TX 77030.
AJR Am J Roentgenol ; 208(4): 916-922, 2017 Apr.
Article em En | MEDLINE | ID: mdl-28140609
ABSTRACT

OBJECTIVE:

The follow-up of breast lesions with imaging-concordant benign histopathology results on MRI-guided vacuum-assisted biopsy (VAB) is not currently standardized. We determined the false omission rate of breast MRI-guided VAB with benign histopathology (negative results) to assess whether breast MRI follow-up is needed. MATERIALS AND

METHODS:

The medical records of patients who underwent 9-gauge breast MRI-guided VAB during 2007-2012 were reviewed retrospectively. Lesions with imaging-concordant benign histopathology results from MRI-guided VAB and surgery or 2 years or more of imaging follow-up were included. The false omission rate (1 - negative predictive value; [number of false-negative results / number of negative results]) of MRI-guided VAB was calculated.

RESULTS:

One hundred sixty-nine lesions were included, and 135 had only imaging follow-up (mammography follow-up range, 17-107 months [median, 52 months]; MRI follow-up range, 5-95 months [median, 35 months]). Of the 135 lesions with only imaging follow-up, 48 had mammography only (range, 26-86 months; median, 52 months), and 87 had mammography (range, 17-107 months; median, 52 months) and MRI (range, 5-95 months; median, 35 months). Thirty-four lesions had surgical correlation, and there were no cases of imaging-surgical discordance. Four malignancies were later diagnosed in the same breast in which MRI-guided VAB had been performed. One (0.6%) malignancy was invasive ductal carcinoma at 1 cm from the MRI-guided VAB site; it was mammographically detected 24 months after MRI-guided VAB. The other three malignancies developed 4 cm or more from the site of MRI-guided VAB one ductal carcinoma in situ (DCIS) detected on mammography 12 months after MRI-guided VAB, one DCIS detected on MRI 24 months after MRI-guided VAB, and one Paget disease lesion detected at physical examination 32 months after MRI-guided VAB.

CONCLUSION:

Breast MRI-guided VAB has a low false omission rate. MRI follow-up of lesions with concordant benign MRI-guided VAB histopathology results may not be warranted.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Neoplasias da Mama / Imagem por Ressonância Magnética Intervencionista / Biópsia Guiada por Imagem Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Biópsia por Agulha / Neoplasias da Mama / Imagem por Ressonância Magnética Intervencionista / Biópsia Guiada por Imagem Idioma: En Ano de publicação: 2017 Tipo de documento: Article