Your browser doesn't support javascript.
loading
Cardiac Resynchronization Therapy Device Implantation in a Patient with Cardiogenic Shock under Percutaneous Mechanical Circulatory Support.
Lim, Kyunghee; Choi, Jin-Oh; Yang, Jeong Hoon; Park, Seung-Jung; Kim, Sun Hwa; Kang, Jiseok; Joh, Hyun Sung; Shin, Sun Hye.
Afiliação
  • Lim K; Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Choi JO; Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Yang JH; Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Park SJ; Division of Cardiology, Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kim SH; Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kang J; Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Joh HS; Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Shin SH; Department of Internal Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Korean Circ J ; 47(1): 132-135, 2017 Jan.
Article em En | MEDLINE | ID: mdl-28154601
ABSTRACT
65-year-old woman was admitted to our hospital with acute decompensated heart failure with reduced left ventricular ejection fraction and severe mitral regurgitation. Electrocardiography revealed a typical left bundle branch block and atrial fibrillation. Her condition deteriorated despite administering high-doses of inotropes and vasopressors. Pending a decision to therapy, venoarterial extracorporeal membrane oxygenation (ECMO) was performed when the patient underwent a cardiogenic shock. Although the hemodynamic status stabilized with ECMO support, weaning the patient from ECMO was not possible. Thus, we decided to perform cardiac resynchronization with defibrillator implantation as a "rescue" therapy. Five days post-implantation, the patient was successfully weaned from ECMO.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article