Practical time considerations for optically stimulated luminescent dosimetry (OSLD) in total body irradiation.
Butson, Martin; Haque, Mamoon; Smith, Leon; Butson, Ethan; Odgers, David; Pope, Dane; Gorjiana, Tina; Whitaker, May; Morales, Johnny; Hong, Angela; Hill, Robin.
Afiliação
  • Butson M; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia. Martin.butson@lh.org.au.
  • Haque M; Institute of Medical Physics, University of Sydney, Camperdown, Australia. Martin.butson@lh.org.au.
  • Smith L; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
  • Butson E; Institute of Medical Physics, University of Sydney, Camperdown, Australia.
  • Odgers D; Sydney Medical School, University of Sydney, Camperdown, Australia.
  • Pope D; Institute of Medical Physics, University of Sydney, Camperdown, Australia.
  • Gorjiana T; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
  • Whitaker M; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
  • Morales J; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
  • Hong A; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
  • Hill R; Dept of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, NSW, Australia.
Australas Phys Eng Sci Med ; 40(1): 167-171, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28194655
ABSTRACT
Total body irradiation (TBI) treatments are used to treat the whole body in preparation for hematopoietic stem cell (or bone marrow) transplantation. Our standard clinical regimen is a 12 Gy in 6 fraction, bi-daily technique using 6 MV X-rays at an extended Source-to-Surface distance (SSD) of 300 cm. Utilizing these characteristics, the beam dose rate is reduced below 7 cGy/min as is standard for TBI treatment. Dose received by the patient is monitored using optically stimulated luminescent dosimetry (OSLD). This work presents some practical calibration corrections based on time-dependant factors for OSLD calibration related to TBI procedure. Results have shown that a negligible difference is seen in OSL sensitivity for 6 MV X-rays irradiated in standard SSD (100 cm) and high dose rate (600 cGy/min) conditions compared to extended SSD (300 cm) and low TBI dose rate (6 cGy/min) conditions. Results have also shown that whilst short term signal fading occurs in the OSL after irradiation at a high dose rate (37% reduction in signal in the first 15 min), thereafter, negligible differences are seen in the OSL signal between 600 and 7 cGy/min irradiations. Thus a direct comparison can be made between calibration OSLs and clinical TBI OSLs between 15 min and 2 h. Finally a table is presented to provide corrections between calibration OSL readout and clinical TBI dose readout for a period up to 7 days. Combining these three results allows users to pre-irradiate their calibration OSLs at standard dose rate and SSD, up to 1 week prior to clinical treatment, and still provide accurate in-vivo dosimetry. This can help with time saving and work efficiency in the clinic.