Your browser doesn't support javascript.
loading
The optimal monochromatic spectral computed tomographic imaging plus adaptive statistical iterative reconstruction algorithm can improve the superior mesenteric vessel image quality.
Yin, Xiao-Ping; Zuo, Zi-Wei; Xu, Ying-Jin; Wang, Jia-Ning; Liu, Huai-Jun; Liang, Guang-Lu; Gao, Bu-Lang.
Afiliação
  • Yin XP; CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000, China.
  • Zuo ZW; CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000, China.
  • Xu YJ; CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000, China.
  • Wang JN; CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000, China.
  • Liu HJ; Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000, China. Electronic address: hebeiliu@outlook.com.
  • Liang GL; CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000, China.
  • Gao BL; Department of Medical Research, Shijiazhuang First Hospital, Shijiazhuang, Hebei, 050011, China. Electronic address: browngao@163.com.
Eur J Radiol ; 89: 47-53, 2017 Apr.
Article em En | MEDLINE | ID: mdl-28267548
ABSTRACT

OBJECTIVE:

To investigate the effect of the optimal monochromatic spectral computed tomography (CT) plus adaptive statistical iterative reconstruction on the improvement of the image quality of the superior mesenteric artery and vein. MATERIALS AND

METHODS:

The gemstone spectral CT angiographic data of 25 patients were reconstructed in the following three groups 70KeV, the optimal monochromatic imaging, and the optimal monochromatic plus 40%iterative reconstruction mode. The CT value, image noises (IN), background CT value and noises, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image scores of the vessels and surrounding tissues were analyzed.

RESULTS:

In the 70KeV, the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group, the mean scores of image quality were 3.86, 4.24 and 4.25 for the superior mesenteric artery and 3.46, 3.78 and 3.81 for the superior mesenteric vein, respectively. The image quality scores for the optimal monochromatic and the optimal monochromatic plus 40% iterative reconstruction groups were significantly greater than for the 70KeV group (P<0.05). The vascular CT value, image noise, background noise, CNR and SNR were significantly (P<0.001) greater in the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group than in the 70KeV group. The optimal monochromatic plus 40% iterative reconstruction group had significantly (P<0.05) lower image and background noise but higher CNR and SNR than the other two groups.

CONCLUSION:

The optimal monochromatic imaging combined with 40% iterative reconstruction using low-contrast agent dosage and low injection rate can significantly improve the image quality of the superior mesenteric artery and vein.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Artéria Mesentérica Superior Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Artéria Mesentérica Superior Idioma: En Ano de publicação: 2017 Tipo de documento: Article