Your browser doesn't support javascript.
loading
Anthropomorphic dual-lattice voxel models for optimizing image quality and dose.
Petoussi-Henss, Nina; Schlattl, Helmut; Becker, Janine; Greiter, Matthias; Zankl, Maria; Hoeschen, Christoph.
Afiliação
  • Petoussi-Henss N; Institute of Radiation Protection , Helmholtz Zentrum München, Neuherberg, Germany.
  • Schlattl H; Institute of Radiation Protection , Helmholtz Zentrum München, Neuherberg, Germany.
  • Becker J; Institute of Radiation Protection , Helmholtz Zentrum München, Neuherberg, Germany.
  • Greiter M; Individual Monitoring Service , Helmholtz Zentrum München, Neuherberg, Germany.
  • Zankl M; Institute of Radiation Protection , Helmholtz Zentrum München, Neuherberg, Germany.
  • Hoeschen C; Otto-von-Guericke University , Medical Systems, Institute of Medical Technology, Magdeburg, Germany.
J Med Imaging (Bellingham) ; 4(1): 013509, 2017 Jan.
Article em En | MEDLINE | ID: mdl-28401175
ABSTRACT
Using numerical simulations, the influence of various imaging parameters on the resulting image can be determined for various imaging technologies. To achieve this, visualization of fine tissue structures needed to evaluate the image quality with different radiation quality and dose is essential. The present work examines a method that employs simulations of the imaging process using Monte Carlo methods and a combination of a standard and higher resolution voxel models. A hybrid model, based on nonlinear uniform rational B-spline and polygon mesh surfaces, was constructed from an existing voxel model of a female patient of a resolution in the range of millimeters. The resolution of the hybrid model was [Formula see text], i.e., substantially finer than that of the original model. Furthermore, a high resolution lung voxel model [[Formula see text] voxel volume, slice thickness [Formula see text]] was developed from the specimen of a left lung lobe. This has been inserted into the hybrid model, substituting its left lung lobe and resulting in a dual-lattice geometry model. "Dual lattice" means, in this context, the combination of voxel models with different resolutions. Monte Carlo simulations of radiographic imaging were performed and the fine structure of the lung was easily recognizable.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article