Your browser doesn't support javascript.
loading
Atrial electromechanical delay in patients undergoing heart transplantation.
Bulut, Mustafa; Evlice, Mert; Celik, Mehmet; Eren, Hayati; Savluk, Ömer F; Acar, Rezzan D; Tabakci, Mustafa; Emiroglu, Mehmet Y; Otcu Nurse, Ozlem; Kargin, Ramazan; Balkanay, Mehmet; Akcakoyun, Mustafa.
Afiliação
  • Bulut M; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Evlice M; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Celik M; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Eren H; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Savluk ÖF; Department of Anesthesia, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Acar RD; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Tabakci M; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Emiroglu MY; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Otcu Nurse O; Department of Cardiovascular Surgery, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Kargin R; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
  • Balkanay M; Department of Cardiovascular Surgery, Katip Celebi University and Ataturk Training and Research Hospital, Izmir, Turkey.
  • Akcakoyun M; Department of Cardiology, Kartal Kosuyolu High Speciality Training and Research Hospital, Istanbul, Turkey.
J Arrhythm ; 33(2): 122-126, 2017 Apr.
Article em En | MEDLINE | ID: mdl-28416978
BACKGROUND: We aimed to assess atrial electromechanical delay (AEMD) in patients who had undergone heart transplantation. METHODS: A total of 32 patients who underwent biatrial anastomosis heart transplantation (24 men, 8 women; mean age: 42±11 years) and 30 healthy volunteers (20 men, 10 women; mean age: 36±13 years) were included in the study. Atrial electromechanical coupling (PA), intra-AEMD, and inter-AEMD were measured. RESULTS: PA lateral (68±7 vs. 51±11 ms, p<0.01), PA septal (50±5 vs. 42±8 ms, p< 0.01) and PA tricuspid (39±6 vs. 36±9 ms, p<0.01), inter-AEMD (PA lateral-PA tricuspid) (27±7 vs. 10±4 ms, p<0.01), left intra-AEMD (PA lateral-PA septal) (18±7 vs. 10±4 ms, p<0.01), right intra-AEMD (PA septal-PA tricuspid) (13±5 vs. 5±3 ms, p<0.01) values were higher in patients who underwent heart transplantation than in a control population. CONCLUSION: Inter-AEMD and intra-AEMD were prolonged in patients who underwent heart transplantation as compared to a control population. This may explain the increased atrial fibrillation and other atrial arrhythmia incidences associated with the biatrial anastomosis heart transplantation technique and may contribute to the treatment of atrial fibrillation in this special patient group.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article