Your browser doesn't support javascript.
loading
Disinfection effect of a continuous-flow ultrasound/ultraviolet baffled reactor at a pilot scale.
Zhou, Xiaoqin; Yan, Yichang; Li, Zifu; Yin, Jie.
Afiliação
  • Zhou X; School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, University of Science and Technology Beijing, Beijing 100083, PR China.
  • Yan Y; School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, University of Science and Technology Beijing, Beijing 100083, PR China.
  • Li Z; School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, University of Science and Technology Beijing, Beijing 100083, PR China. Electronic address: zifulee@aliyun.com.
  • Yin J; School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, University of Science and Technology Beijing, Beijing 100083, PR China.
Ultrason Sonochem ; 37: 114-119, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28427613
An ultrasound/ultraviolet (US/UV) baffled reactor was developed to fill the gap in ultraviolet (UV) disinfection associated with disinfection efficiency. According to the previously selected operational condition, a continuous-flow US/UV baffled reactor was continuously operated in a wastewater treatment plant at a pilot scale for nearly three months, and the disinfection influent and effluent were analyzed, including fecal coliforms, Escherichia coli, and fecal streptococci. The US/UV baffled reactor could guarantee a high effluent disinfection performance in terms of fecal coliforms removal even with the fluctuation of the secondary effluent. All the disinfected effluents satisfied the requirement of the "Pollutants Discharge Standard of Municipal Wastewater Treatment Plant in China" (fecal coliforms below 1000CFU/L for class 1A), and 87% of the tested fecal coliforms concentration in the disinfected effluent was below 100CFU/L, nearly eliminating all fecal coliforms. Further analysis of the E. coli and fecal streptococci showed the broad disinfection ability and high disinfection efficiency of the US/UV baffled reactor. The flexibility of the specific energy consumption for the disinfection system depends on the water quality.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Raios Ultravioleta / Desinfecção / Ondas Ultrassônicas Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Raios Ultravioleta / Desinfecção / Ondas Ultrassônicas Idioma: En Ano de publicação: 2017 Tipo de documento: Article