Your browser doesn't support javascript.
loading
Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) for Rapid Determination of Microbial Cell Lipid Content: Correlation with Gas Chromatography-Mass Spectrometry (GC-MS).
Millan-Oropeza, Aaron; Rebois, Rolando; David, Michelle; Moussa, Fathi; Dazzi, Alexandre; Bleton, Jean; Virolle, Marie-Joelle; Deniset-Besseau, Ariane.
Afiliação
  • Millan-Oropeza A; 1 Institute for Integrative Biology of the Cell (I2BC), CEA, CNRS, Université Paris-Sud, Gif-sur-Yvette cedex, France.
  • Rebois R; 2 Laboratoire de Chimie Physique (LCP), CNRS, Université Paris-Sud, Orsay cedex, France.
  • David M; 1 Institute for Integrative Biology of the Cell (I2BC), CEA, CNRS, Université Paris-Sud, Gif-sur-Yvette cedex, France.
  • Moussa F; 3 Lip(Sys)2, LETIAM§, Univ. Paris-Sud, Université Paris-Saclay. IUT d'Orsay, Plateau de Moulon, F-91400, Orsay, France.
  • Dazzi A; 2 Laboratoire de Chimie Physique (LCP), CNRS, Université Paris-Sud, Orsay cedex, France.
  • Bleton J; 3 Lip(Sys)2, LETIAM§, Univ. Paris-Sud, Université Paris-Saclay. IUT d'Orsay, Plateau de Moulon, F-91400, Orsay, France.
  • Virolle MJ; 1 Institute for Integrative Biology of the Cell (I2BC), CEA, CNRS, Université Paris-Sud, Gif-sur-Yvette cedex, France.
  • Deniset-Besseau A; 2 Laboratoire de Chimie Physique (LCP), CNRS, Université Paris-Sud, Orsay cedex, France.
Appl Spectrosc ; 71(10): 2344-2352, 2017 Oct.
Article em En | MEDLINE | ID: mdl-28485613
ABSTRACT
There is a growing interest worldwide for the production of renewable oil without mobilizing agriculture lands; fast and reliable methods are needed to identify highly oleaginous microorganisms of potential industrial interest. The aim of this study was to demonstrate the relevance of attenuated total reflection (ATR) spectroscopy to achieve this goal. To do so, the total lipid content of lyophilized samples of five Streptomyces strains with varying lipid content was assessed with two classical quantitative but time-consuming methods, gas chromatography-mass spectrometry (GC-MS) and ATR Fourier transform infrared (ATR FT-IR) spectroscopy in transmission mode with KBr pellets and the fast ATR method, often questioned for its lack of reliability. A linear correlation between these three methods was demonstrated allowing the establishment of equations to convert ATR values expressed as CO/amide I ratio, into micrograms of lipid per milligram of biomass. The ATR method proved to be as reliable and quantitative as the classical GC-MS and FT-IR in transmission mode methods but faster and more reproducible than the latter since it involves far less manipulation for sample preparation than the two others. Attenuated total reflection could be regarded as an efficient fast screening method to identify natural or genetically modified oleaginous microorganisms by the scientific community working in the field of bio-lipids.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Streptomyces / Espectroscopia de Infravermelho com Transformada de Fourier / Ácidos Graxos / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Streptomyces / Espectroscopia de Infravermelho com Transformada de Fourier / Ácidos Graxos / Cromatografia Gasosa-Espectrometria de Massas Idioma: En Ano de publicação: 2017 Tipo de documento: Article