Your browser doesn't support javascript.
loading
Quality assessment and transfusion efficacy of buffy coat-derived platelet concentrates washed with platelet additive solution.
Fernández-Muñoz, Hermógenes; Castilla-Llorente, Cristina; Plaza, Eva M; Martínez-Millán, Cristina; Heras, Inmaculada; Iniesta, Pastora; Amigo, María L; Ferrer-Marin, Francisca; Candela, María J; Lozano, María L; Vicente, Vicente; Rivera, José.
Afiliação
  • Fernández-Muñoz H; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Castilla-Llorente C; Haematology and Blood Therapy Service, "Rafael Méndez" University Hospital, Lorca, Spain.
  • Plaza EM; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Martínez-Millán C; Haematology Service, "Gustave Roussy" Institute, Villejuif, France.
  • Heras I; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Iniesta P; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Amigo ML; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Ferrer-Marin F; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Candela MJ; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Lozano ML; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Vicente V; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
  • Rivera J; Haematology and Medical Oncology Service, Morales Meseguer University Hospital, Regional Blood Donation Centre, University of Murcia, IMIB-Arrixaca, CIBERER, Murcia, Spain.
Blood Transfus ; 16(3): 273-278, 2018 05.
Article em En | MEDLINE | ID: mdl-28488971
ABSTRACT

BACKGROUND:

Transfusion of washed platelet concentrates (W-PC) is recommended for some patients, such as those who have had previous severe allergic transfusion reactions. However, we still lack a standardised method for preparing these products. Here, we assessed the effect of a manual washing procedure on in vitro platelet quality and on the transfusion efficacy of W-PCs. MATERIALS AND

METHODS:

Buffy coat-derived W-PC in Composol solution were prepared by one-step centrifugation. Platelet activation and function were evaluated before and after washing by means of (i) CD62 expression by flow cytometry; (ii) platelet aggregation (LTA); and (iii) the VerifyNow® P2Y12 test. A pilot prospective transfusion study was carried out in 11 onco-hematology patients receiving, in a short time, two consecutive transfusions one with standard PC (S-PC) and one with W-PC. The post-transfusion platelet increment, the 1 h and 24 h corrected count increment (CCI) and occurrence of bleeding events were used as indices of transfusion efficacy.

RESULTS:

Platelet recovery in W-PC was 84.8±5.4%. Washing slightly increased platelet activation in W-PC vs pre-washed samples (% CD62+ platelets 23.6±7 vs 14.8±1; p=0.03). As compared to prewash samples, platelet reactivity of W-PC as measured by VerifyNow® P2Y12 was significantly lower with ADP (PRU 32.2±37.7 vs 4.2±2.4, p=0.027), but similar using TRAP. Platelet aggregation responses to TRAP, collagen, ristocetin and arachidonic acid were maintained in W-PC. The pilot transfusion trial showed similar 1 h (13.5±5.6 vs 11.5±7.3, p=0.49) and 24 h (11±7.2 vs 9±6.5, p=0.48) CCI for S-PC and W-PC. Transfusion of W-PC was not associated with an increased number of bleeding events.

DISCUSSION:

We have set up a simple method to obtain buffy-coat-derived W-PC, which has minor effects on in vitro platelet quality and transfusion effectiveness. This procedure can be easily implemented in transfusion centres for on-demand preparation of washed platelets.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Plaquetoferese / Transfusão de Plaquetas / Buffy Coat Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Plaquetoferese / Transfusão de Plaquetas / Buffy Coat Idioma: En Ano de publicação: 2018 Tipo de documento: Article