Usefulness of three-dimensional magnetic resonance cholangiopancreatography with partial maximum intensity projection for diagnosing autoimmune pancreatitis.
Yanagisawa, Shin; Fujinaga, Yasunari; Watanabe, Takayuki; Maruyama, Masahiro; Muraki, Takashi; Takahashi, Masaaki; Fujita, Akira; Fujita, Sachie; Kurozumi, Masahiro; Ueda, Kazuhiko; Hamano, Hideaki; Kawa, Shigeyuki; Kadoya, Masumi.
Afiliação
  • Yanagisawa S; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan. Electronic address: shiny@shinshu-u.ac.jp.
  • Fujinaga Y; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Watanabe T; Department of Gastroenterology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Maruyama M; Department of Gastroenterology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Muraki T; Department of Gastroenterology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Takahashi M; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Fujita A; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Fujita S; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Kurozumi M; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Ueda K; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Hamano H; Department of Medical informatics, Gastroenterology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Kawa S; Center for Health, Safety, and Environmental Management, Shinshu University, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
  • Kadoya M; Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
Pancreatology ; 17(4): 567-571, 2017.
Article em En | MEDLINE | ID: mdl-28506431
ABSTRACT

PURPOSE:

To compare three-dimensional magnetic resonance cholangiopancreatography (MRCP) with/without partial maximum intensity projection (MIP) and endoscopic retrograde cholangiopancreatography (ERCP) in patients with autoimmune pancreatitis (AIP). MATERIALS AND

METHODS:

Three-dimensional MRCP and ERCP images were retrospectively analyzed in 24 patients with AIP. We evaluated the narrowing length of the main pancreatic duct (NR-MPD), multiple skipped MPD narrowing (SK-MPD), and side branches arising from the narrowed portion of the MPD (SB-MPD) using four MRCP datasets 5 original images (MIP5), 10 original images (MIP10), all original images (full-MIP), and a combination of these three datasets (a-MIP). The images were scored using a 3- or 5-point scale. The scores of the four MRCP datasets were statistically analyzed, and the positive rate of each finding was compared between MRCP and ERCP.

RESULTS:

The median scores for SB-MPD on MIP5 and a-MIP were significantly higher than those on MIP10 and full-MIP. In other words, partial MIP is superior to full-MIP for visualization of detailed structures. The positive rate for SB-MPD on full-MIP was significantly lower than that on ERCP, whereas the positive rate on MIP5, MIP10, and a-MIP was not significantly different from that on ERCP. Moreover, the positive rate for NR-MPD and SK-MPD on the MRCP images was significantly higher than that on the ERCP images.

CONCLUSION:

Partial MIP is useful for evaluating the MPD and is comparable with ERCP for diagnosing AIP.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article