Your browser doesn't support javascript.
loading
Determination of reference intervals for urinary steroid profiling using a newly validated GC-MS/MS method.
de Jong, Wilhelmina H A; Buitenwerf, Edward; Pranger, Alle T; Riphagen, Ineke J; Wolffenbuttel, Bruce H R; Kerstens, Michiel N; Kema, Ido P.
Afiliação
  • de Jong WHA; .
  • Buitenwerf E; .
  • Pranger AT; .
  • Riphagen IJ; .
  • Wolffenbuttel BHR; .
  • Kerstens MN; .
  • Kema IP; .
Clin Chem Lab Med ; 56(1): 103-112, 2017 Nov 27.
Article em En | MEDLINE | ID: mdl-28598795
ABSTRACT

BACKGROUND:

Urinary steroid profiling (USP) is a powerful diagnostic tool to asses disorders of steroidogenesis. Pre-analytical factors such as age, sex and use of oral contraceptive pills (OCP) may affect steroid hormone synthesis and metabolism. In general, USP reference intervals are not adjusted for these variables. In this study we aimed to establish such reference intervals using a newly-developed and validated gas chromatography with tandem mass spectrometry detection method (GC-MS/MS).

METHODS:

Two hundred and forty healthy subjects aged 20-79 years, stratified into six consecutive decade groups each containing 20 males and 20 females, were included. None of the subjects used medications. In addition, 40 women aged 20-39 years using OCP were selected. A GC-MS/MS assay, using hydrolysis, solid phase extraction and double derivatization, was extensively validated and applied for determining USP reference intervals.

RESULTS:

Androgen metabolite excretion declined with age in both men and women. Cortisol metabolite excretion remained constant during life in both sexes but increased in women 70-79 years of age. Progesterone metabolite excretion peaked in 30-39-year-old women and declined afterwards. Women using OCP had lower excretions of androgen metabolites, progesterone metabolites and cortisol metabolites. Method validation results met prerequisites and revealed the robustness of the GC-MS/MS method.

CONCLUSIONS:

We developed a new GC-MS/MS method for USP which is applicable for high throughput analysis. Widely applicable age and sex specific reference intervals for 33 metabolites and their diagnostic ratios have been defined. In addition to age and gender, USP reference intervals should be adjusted for OCP use.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esteroides / Cromatografia Gasosa / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Esteroides / Cromatografia Gasosa / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2017 Tipo de documento: Article