Feasibility of Combined Doppler-ECG Assessment of Internal Jugular Veins.
Dierickx, Inge; Van Hooland, Simon; Tomsin, Kathleen; Vanhercke, Daniel; Cools, Wilfried; Fransen, Hendrik; Gyselaers, Wilfried.
Afiliação
  • Dierickx I; Department of Obstetrics and Gynecology, Algemeen Ziekenhuis Sint Lucas, Ghent, Belgium; Department of Physiology, University Hasselt, Hasselt, Belgium. Electronic address: inge.dierickx@azstlucas.be.
  • Van Hooland S; Department of Nephrology, Algemeen Ziekenhuis Sint Lucas, Ghent, Belgium.
  • Tomsin K; Department of Physiology, University Hasselt, Hasselt, Belgium; Department of Obstetrics and Gynecology, Ziekenhuis Oost Limburg, Genk, Belgium; Department of Obstetrics and Gynecology, Maastricht University Medical Centre, Maastricht, The Netherlands.
  • Vanhercke D; Department of Cardiology, Algemeen Ziekenhuis Sint Lucas, Ghent, Belgium.
  • Cools W; I-BioStat, University Hasselt, Hasselt, Belgium.
  • Fransen H; Department of Radiology, Algemeen Ziekenhuis Sint Lucas, Ghent, Belgium.
  • Gyselaers W; Department of Physiology, University Hasselt, Hasselt, Belgium; Department of Obstetrics and Gynecology, Ziekenhuis Oost Limburg, Genk, Belgium.
Ultrasound Med Biol ; 43(9): 1853-1860, 2017 09.
Article em En | MEDLINE | ID: mdl-28625559
ABSTRACT
A standardized combined Doppler-electrocardiography technique was developed for measurement of the triphasic waveform characteristics in the internal jugular vein. Flow velocities at the A, X, V and Y peaks, the RR interval and the PA and RX times were measured. From these the venous impedance index ([X-A]/X) and the ratios PA/RR and RX/RR were calculated. Six measurements were performed at three different locations by two ultrasonographers in 21 randomly selected pregnant and non-pregnant women. Statistical models proved the feasibility and reproducibility of this technique, with the highest concordance correlation coefficients in the right distal internal vein. Bootstrapping revealed that repeating the measurements more than four times would not significantly enhance the precision of the estimated mean. Concordance correlation coefficients for the venous impedance index, PA time and PA/RR ratio were >0.63 for all three locations, proving their possible use in ongoing and future studies, analogous to previous studies in kidney and liver.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassonografia Doppler / Eletrocardiografia / Veias Jugulares Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassonografia Doppler / Eletrocardiografia / Veias Jugulares Idioma: En Ano de publicação: 2017 Tipo de documento: Article