Your browser doesn't support javascript.
loading
Design of a shielded coil element of a matrix gradient coil.
Jia, Feng; Littin, Sebastian; Layton, Kelvin J; Kroboth, Stefan; Yu, Huijun; Zaitsev, Maxim.
Afiliação
  • Jia F; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany. Electronic address: feng.jia@uniklinik-freiburg.de.
  • Littin S; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany.
  • Layton KJ; Institute for Telecommunications Research, University of South Australia, Mawson Lakes, SA 5095, Australia.
  • Kroboth S; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany.
  • Yu H; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany.
  • Zaitsev M; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany.
J Magn Reson ; 281: 217-228, 2017 08.
Article em En | MEDLINE | ID: mdl-28628908
ABSTRACT
The increasing interest in spatial encoding with non-linear magnetic fields has intensified the need for coils that generates such fields. Matrix coils consisting of multiple coil elements appear to offer a high flexibility in generating customized encoding fields and are particularly promising for localized high resolution imaging applications. However, coil elements of existing matrix coils were primarily designed and constructed for better shimming and therefore are not expected to achieve an optimal performance for local spatial encoding. Moreover, eddy current properties of such coil elements were not fully explored. In this work, an optimization problem is formulated based on the requirement of local non-linear encoding and eddy current reduction that results in novel designs of coil elements for an actively-shielded matrix gradient coil. Two metrics are proposed to assess the performance of different coil element designs. The results are analyzed to reveal new insights into coil element design.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article