Fast x-ray detector system with simultaneous measurement of timing and energy for a single photon.
Masuda, T; Okubo, S; Hara, H; Hiraki, T; Kitao, S; Miyamoto, Y; Okai, K; Ozaki, R; Sasao, N; Seto, M; Uetake, S; Yamaguchi, A; Yoda, Y; Yoshimi, A; Yoshimura, K.
Afiliação
  • Masuda T; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Okubo S; Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan.
  • Hara H; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Hiraki T; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Kitao S; Research Reactor Institute, Kyoto University, Osaka 590-0494, Japan.
  • Miyamoto Y; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Okai K; Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan.
  • Ozaki R; Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan.
  • Sasao N; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Seto M; Research Reactor Institute, Kyoto University, Osaka 590-0494, Japan.
  • Uetake S; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Yamaguchi A; Quantum Metrology Laboratory, RIKEN, Saitama 351-0198, Japan.
  • Yoda Y; Japan Synchrotron Radiation Research Institute, Hyogo 679-5198, Japan.
  • Yoshimi A; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
  • Yoshimura K; Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan.
Rev Sci Instrum ; 88(6): 063105, 2017 Jun.
Article em En | MEDLINE | ID: mdl-28667968
ABSTRACT
We developed a fast X-ray detector system for nuclear resonant scattering (NRS) experiments. Our system employs silicon avalanche photo-diode (Si-APD) as a fast X-ray sensor. The system is able to acquire both timing and energy of a single X-ray photon simultaneously in a high rate condition, 106 counts per second for one Si-APD. The performance of the system was investigated in SPring-8, a synchrotron radiation facility in Japan. Good time resolution of 120 ps (FWHM) was achieved with a slight tail distribution in the time spectrum by a level of 10-9 at 1 ns apart from the peak. Using this system, we successfully observed the NRS from the 26.27-keV level of mercury-201, which has a half-life of 630(50) ps. We also demonstrated the reduction of background events caused by radioactive decays in a radioactive sample by discriminating photon energy.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article