Zwitterionic hydrophilic interaction liquid chromatography-tandem mass spectrometry with HybridSPE-precipitation for the determination of intact cisplatin in human plasma.
Xie, Feifan; Colin, Pieter; Van Bocxlaer, Jan.
Afiliação
  • Xie F; Laboratory of Medical Biochemistry and Clinical Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium. Electronic address: Feifan.Xie@UGent.be.
  • Colin P; Laboratory of Medical Biochemistry and Clinical Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium; Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands. Electronic address: Pieter.Colin@UGent.be.
  • Van Bocxlaer J; Laboratory of Medical Biochemistry and Clinical Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium. Electronic address: Jan.VanBocxlaer@UGent.be.
Talanta ; 174: 171-178, 2017 Nov 01.
Article em En | MEDLINE | ID: mdl-28738565
ABSTRACT
Cisplatin is a first-line chemotherapeutic for the treatment of a wide variety of cancers since its discovery in the 1960s. Although various techniques have been reported for the measurement of total platinum in biological matrices, such as inductively coupled plasma-mass spectrometry and derivatization procedures, a specific, sensitive and robust assay for the quantification of intact cisplatin is still lacking. Therefore, we present a rapid, selective, sensitive, and reliable UHPLC-MS/MS based method for the determination of intact cisplatin in human plasma in support of a Phase II clinical trial. The optimal chromatographic behavior of cisplatin was achieved on a Syncronis HILIC column (50 × 2.1mm, 1.7µm, zwitterionic stationary phase). The retention behavior of cisplatin on this zwitterion-based stationary phase was well described by an adsorptive interaction model. A simple sample preparation based on protein precipitation combined with the removal of phospholipids by HybridSPE-precipitation was developed. The method was proven to be free of a relative matrix effect. The assay was validated within a range of 20 - 10,000ng/mL using 100µL of plasma sample. The intra and inter-day precisions were all less than 7.6%, and none of the bias was greater than 13.1%, thus corroborating that the developed method is precise and accurate. As a proof of concept, the assay has been successfully applied to plasma samples obtained from different patients who were enrolled in the Phase II trial and were treated with cisplatin.