Your browser doesn't support javascript.
loading
What is the impact of the fluid challenge technique on diagnosis of fluid responsiveness? A systematic review and meta-analysis.
Toscani, Laura; Aya, Hollmann D; Antonakaki, Dimitra; Bastoni, Davide; Watson, Ximena; Arulkumaran, Nish; Rhodes, Andrew; Cecconi, Maurizio.
Afiliação
  • Toscani L; General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.
  • Aya HD; Cristo Re Hospital, Via delle Calasanziane 25, 00167, Rome, Italy.
  • Antonakaki D; General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK. hollmann.aya@nhs.net.
  • Bastoni D; Anaesthetic Department, East Surrey Hospital, Surrey & Sussex Healthcare Trust, Canada Avenue, Redhill, Surrey, RH1 5 RH, UK. hollmann.aya@nhs.net.
  • Watson X; General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.
  • Arulkumaran N; Cardiology Department, Broomfield Hospital, Mid-Essex Healthcare Trust, Court Road, Broomfield, Chelmsford, CM1 7ET, UK.
  • Rhodes A; General Intensive Care Unit, Adult Intensive Care Directorate, St George's University Hospitals, NHS Foundation Trust and St George's University of London, St James Wing, First Floor, Blackshaw Road, London, SW17 0QT, UK.
  • Cecconi M; Dipartimento di Medicina Sperimentale, Azienda Ospedaliero-Universitaria di Parma, Via Gramsci 14, 43126, Parma, Italy.
Crit Care ; 21(1): 207, 2017 Aug 04.
Article em En | MEDLINE | ID: mdl-28774325
ABSTRACT

BACKGROUND:

The fluid challenge is considered the gold standard for diagnosis of fluid responsiveness. The objective of this study was to describe the fluid challenge techniques reported in fluid responsiveness studies and to assess the difference in the proportion of 'responders,' (PR) depending on the type of fluid, volume, duration of infusion and timing of assessment.

METHODS:

Searches of MEDLINE and Embase were performed for studies using the fluid challenge as a test of cardiac preload with a description of the technique, a reported definition of fluid responsiveness and PR. The primary outcome was the mean PR, depending on volume of fluid, type of fluids, rate of infusion and time of assessment.

RESULTS:

A total of 85 studies (3601 patients) were included in the analysis. The PR were 54.4% (95% CI 46.9-62.7) where <500 ml was administered, 57.2% (95% CI 52.9-61.0) where 500 ml was administered and 60.5% (95% CI 35.9-79.2) where >500 ml was administered (p = 0.71). The PR was not affected by type of fluid. The PR was similar among patients administered a fluid challenge for <15 minutes (59.2%, 95% CI 54.2-64.1) and for 15-30 minutes (57.7%, 95% CI 52.4-62.4, p = 1). Where the infusion time was ≥30 minutes, there was a lower PR of 49.9% (95% CI 45.6-54, p = 0.04). Response was assessed at the end of fluid challenge, between 1 and 10 minutes, and >10 minutes after the fluid challenge. The proportions of responders were 53.9%, 57.7% and 52.3%, respectively (p = 0.47).

CONCLUSIONS:

The PR decreases with a long infusion time. A standard technique for fluid challenge is desirable.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ressuscitação / Hidratação / Hemodinâmica Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ressuscitação / Hidratação / Hemodinâmica Idioma: En Ano de publicação: 2017 Tipo de documento: Article