Your browser doesn't support javascript.
loading
Results at 7years after cross-linking procedure in keratoconic patients.
Nicula, C; Nicula, D; Pop, R N.
Afiliação
  • Nicula C; Cluj-Napoca University Ophthalmology Clinic, Cluj County Hospital, No. 3-5, Clinicilor Street, 400006 Cluj-Napoca, Romania; Iuliu Hațieganu University of Medicine and Pharmacy, Faculty of Medicine, No. 4, Louis Pasteur Street, 400349 Cluj-Napoca, Romania; OCULENS Ophthalmology Private Clinic, No. 7, Nicolae Pascaly Street, 400431 Cluj-Napoca, Romania.
  • Nicula D; OCULENS Ophthalmology Private Clinic, No. 7, Nicolae Pascaly Street, 400431 Cluj-Napoca, Romania.
  • Pop RN; OCULENS Ophthalmology Private Clinic, No. 7, Nicolae Pascaly Street, 400431 Cluj-Napoca, Romania. Electronic address: radupop1985@yahoo.com.
J Fr Ophtalmol ; 40(7): 535-541, 2017 Sep.
Article em En | MEDLINE | ID: mdl-28802685
PURPOSE: Long-term evaluation of functional results based on visual acuity, keratometry, spherical equivalent and refractive cylinder in patients with progressive keratoconus treated with corneal collagen cross-linking (CXL). MATERIALS AND METHODS: We studied a group of 114 eyes of 91 consecutive patients treated from 2006 to 2009 by "Epi-off type" CXL. In the preoperative period, all patients had a complete ophthalmologic examination. The inclusion criteria were: patients aged 15 to 54years, with various stages of keratoconus, with a corneal thickness of at least 400µm at the thinnest point. The exclusion criteria were: patients with a corneal thickness of less than 400µm at the thinnest point, with Vogt's striae or herpetic keratitis, dry eye syndrome or aphakia. The patients were then followed at 1, 3 and 6months, and then every year between 1 and 7years postoperatively. RESULTS: There was a decrease in the minimum K and maximum K, respectively 1.6 and 2.0, at 7years postop. (P<0.05). The cylinder decreased from -4.45 D to -3.50 D at 7 years postop (P<0.05). The spherical equivalent decreased by 1.66 D at 7 years (P<0.05). Uncorrected visual acuity increased from an average of 0.78 to 0.679 log MAR (P<0.05) at 7 years postop. The best-corrected visual acuity increased from a mean of 0.64 to 0.52 log Mar (P<0.05) at 7 years postop. CONCLUSIONS: The results of CXL were stable at 7 years in all patients, consisting of reduction of keratometric values and refraction, and improvement in visual acuity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotoquimioterapia / Reagentes de Ligações Cruzadas / Ceratocone Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotoquimioterapia / Reagentes de Ligações Cruzadas / Ceratocone Idioma: En Ano de publicação: 2017 Tipo de documento: Article