Your browser doesn't support javascript.
loading
Uniform field loop-gap resonator and rectangular TEU02 for aqueous sample EPR at 94GHz.
Sidabras, Jason W; Sarna, Tadeusz; Mett, Richard R; Hyde, James S.
Afiliação
  • Sidabras JW; Max Planck for Chemical Energy Conversion, Department of Biophysical Chemistry, Mülheim an der Ruhr 45468, Germany; Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI 53226-0509, United States. Electronic address: jason.sidabras@gmail.com.
  • Sarna T; Department of Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Kraków, Poland.
  • Mett RR; Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI 53226-0509, United States; Milwaukee School of Engineering, Department of Physics and Chemistry, Milwaukee, WI 53202-3109, United States.
  • Hyde JS; Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI 53226-0509, United States.
J Magn Reson ; 282: 129-135, 2017 09.
Article em En | MEDLINE | ID: mdl-28803092
ABSTRACT
In this work we present the design and implementation of two uniform-field resonators a seven-loop-six-gap loop-gap resonator (LGR) and a rectangular TEU02 cavity resonator. Each resonator has uniform-field-producing end-sections. These resonators have been designed for electron paramagnetic resonance (EPR) of aqueous samples at 94GHz. The LGR geometry employs low-loss Rexolite end-sections to improve the field homogeneity over a 3mm sample region-of-interest from near-cosine distribution to 90% uniform. The LGR was designed to accommodate large degassable Polytetrafluorethylen (PTFE) tubes (0.81mm O.D.; 0.25mm I.D.) for aqueous samples. Additionally, field modulation slots are designed for uniform 100kHz field modulation incident at the sample. Experiments using a point sample of lithium phthalocyanine (LiPC) were performed to measure both the uniformity of the microwave magnetic field and 100kHz field modulation, and confirm simulations. The rectangular TEU02 cavity resonator employs over-sized end-sections with sample shielding to provide an 87% uniform field for a 0.1×2×6mm3 sample geometry. An evanescent slotted window was designed for light access to irradiate 90% of the sample volume. A novel dual-slot iris was used to minimize microwave magnetic field perturbations and maintain cross-sectional uniformity. Practical EPR experiments using the application of light irradiated rose bengal (4,5,6,7-tetrachloro-2',4',5',7'-tetraiodofluorescein) were performed in the TEU02 cavity. The implementation of these geometries providing a practical designs for uniform field resonators that continue resonator advancements towards quantitative EPR spectroscopy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Água / Espectroscopia de Ressonância de Spin Eletrônica Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Água / Espectroscopia de Ressonância de Spin Eletrônica Idioma: En Ano de publicação: 2017 Tipo de documento: Article