Your browser doesn't support javascript.
loading
Factors affecting variability in PM2.5 exposure concentrations in a metro system.
Li, Zhiyuan; Che, Wenwei; Frey, H Christopher; Lau, Alexis K H.
Afiliação
  • Li Z; Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. Electronic address: zliar@connect.ust.hk.
  • Che W; Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China; Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. Electronic ad
  • Frey HC; Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China; Department of Civil, Construction and Environmental Engineering, North Carolina State University, Campus Box 7908, Raleigh, NC 27695-7908, United States. Electr
  • Lau AKH; Division of Environment and Sustainability, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China; Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China. Electronic ad
Environ Res ; 160: 20-26, 2018 01.
Article em En | MEDLINE | ID: mdl-28941800
ABSTRACT
The objectives of this study were to (1) evaluate PM2.5 inflow to metro train cabins when doors open at stations; (2) assess the spatial and temporal variability in PM2.5 exposure concentration; and (3) quantify the relationship between in-cabin concentration versus outdoor and non-ambient PM2.5. We measured in-cabin PM2.5 concentrations using portable monitors at the door-side and center of a train cabin simultaneously on a Hong Kong metro line. In addition, platform and in-cabin pollutant concentrations near a train door were simultaneously measured. Short-term spikes in PM2.5 concentrations typically occur near train doors when doors open, related to inflow of ambient air aboveground and tunnel air underground. In-cabin PM2.5 exposure concentrations are typically lower away from the doors when the doors open. PM2.5 concentrations inside train cabins and on station platform operating above-ground are more influenced, compared to underground, by outdoor PM2.5. Moreover, non-ambient sources contribute approximately 50% of train in-cabin and station platform PM2.5 concentrations during underground operation. The results help more accurately quantify commuting PM2.5 exposure on a metro system, and can be used to improve population-based exposure simulation models.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Material Particulado / Instalações de Transporte Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Material Particulado / Instalações de Transporte Idioma: En Ano de publicação: 2018 Tipo de documento: Article