Your browser doesn't support javascript.
loading
Improvement of the activity measurement method for solid dosimeters emitting X-rays.
Domergue, C; Riffaud, J; Lépy, M-C; Destouches, C; Thiollay, N; Philibert, H; Vigneau, O; Gravier, L; Girard, J M; Bonora, J.
Afiliação
  • Domergue C; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France. Electronic address: christophe.domergue@cea.fr.
  • Riffaud J; CEA, LIST, Laboratoire National Henri Becquerel (LNE-LNHB), CEA-Saclay, Bât 602, C 111, 91191 Gif-sur-Yvette CEDEX, France.
  • Lépy MC; CEA, LIST, Laboratoire National Henri Becquerel (LNE-LNHB), CEA-Saclay, Bât 602, C 111, 91191 Gif-sur-Yvette CEDEX, France.
  • Destouches C; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France.
  • Thiollay N; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France.
  • Philibert H; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France.
  • Vigneau O; CEA, DEN, DEC, Laboratoire d'Analyses Radiochimiques et Chimiques, Cadarache 13108 Saint Paul-lez-Durance, France.
  • Gravier L; CEA, DEN, DEC, Laboratoire d'Analyses Radiochimiques et Chimiques, Cadarache 13108 Saint Paul-lez-Durance, France.
  • Girard JM; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France.
  • Bonora J; CEA, DEN, DER, Laboratoire de Dosimétrie, Capteurs et Instrumentation (LDCI), Cadarache, 13108 Saint Paul-lez-Durance, France.
Appl Radiat Isot ; 134: 182-189, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29066050
ABSTRACT
Today, there is growing interest for neutrons in the intermediate energy range between 100keV and 1MeV, which are responsible for damaging materials in reactor. To improve this deficiency, we use rhodium and niobium which, through the inelastic neutron scattering reaction, leads to the formation of 103mRh and 93mNb low-energy X-emitters. This paper describes the improvements and validation made on this type of complex measurement by X spectrometry self-attenuation, fluorescence correction, and emission intensity were poorly known previously.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article