Your browser doesn't support javascript.
loading
241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL.
Pereira, W W; Estrada, J J S; Patrão, K C S; Alves, C F E; Magalhães, L A G; Leite, S P.
Afiliação
  • Pereira WW; Laboratório Nacional de Metrologia das Radiações Ionizantes LNMRI/IRD, Av. Salvador Allende, s/n, Barra da Tijuca, Rio de Janeiro, RJ, Brazil.
  • Estrada JJS; Fundação Técnico Educacional Souza Marques, FTESM, Av. Ernani Cardoso, 335, Cascadura, Rio de Janeiro, RJ, Brazil.
  • Patrão KCS; Universidade do Estado do Rio de Janeiro DBB/IBRAG/UERJ, Rua São Francisco Xavier, 524, Maracanã, Pavilhão Haroldo Lisboa da Cunha, sala 136, Térreo, Rio de Janeiro, RJ, Brazil.
  • Alves CFE; Laboratório Nacional de Metrologia das Radiações Ionizantes LNMRI/IRD, Av. Salvador Allende, s/n, Barra da Tijuca, Rio de Janeiro, RJ, Brazil.
  • Magalhães LAG; Universidade do Estado do Rio de Janeiro DBB/IBRAG/UERJ, Rua São Francisco Xavier, 524, Maracanã, Pavilhão Haroldo Lisboa da Cunha, sala 136, Térreo, Rio de Janeiro, RJ, Brazil.
  • Leite SP; Universidade do Estado do Rio de Janeiro DBB/IBRAG/UERJ, Rua São Francisco Xavier, 524, Maracanã, Pavilhão Haroldo Lisboa da Cunha, sala 136, Térreo, Rio de Janeiro, RJ, Brazil.
Radiat Prot Dosimetry ; 180(1-4): 29-32, 2018 Aug 01.
Article em En | MEDLINE | ID: mdl-29136235
ABSTRACT
The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 µSv/h.