Your browser doesn't support javascript.
loading
Ionic liquid solvent bar micro-extraction of CdCln(n-2)- species for ultra-trace Cd determination in seawater.
Herce-Sesa, Belén; López-López, José A; Moreno, Carlos.
Afiliação
  • Herce-Sesa B; Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto Universitario de Investigación Marina (INMAR), International Campus of Global Excellence (Cei·Mar), University of Cádiz, Av. República Saharaui, Puerto Real, 11510 Cádiz, Spain.
  • López-López JA; Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto Universitario de Investigación Marina (INMAR), International Campus of Global Excellence (Cei·Mar), University of Cádiz, Av. República Saharaui, Puerto Real, 11510 Cádiz, Spain. Electronic address: joseantonio.lopezlopez@uca.es.
  • Moreno C; Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, Instituto Universitario de Investigación Marina (INMAR), International Campus of Global Excellence (Cei·Mar), University of Cádiz, Av. República Saharaui, Puerto Real, 11510 Cádiz, Spain.
Chemosphere ; 193: 306-312, 2018 Feb.
Article em En | MEDLINE | ID: mdl-29145092
ABSTRACT
Water analysis of trace metals has been benefited by recent studies on sample preparation by liquid micro-extraction. However, there are still limitations for its application to seawater, such as the need of additives to preserve the sample or the availability of chemical extractants for the selective extraction from highly saline samples. In this work, a three phase solvent bar micro-extraction (3SBME) system containing the ionic liquid trioctylmethylammonium chloride (Aliquat® 336) has been used for isolation and pre-concentration of Cd from seawater samples, due to its ability for ionic exchange of CdCln(n-2)-. The system was optimized to work at the natural pH of seawater, and conditions for application to real samples were 0.18 M Aliquat® 336 dissolved in kerosene with 0.25 M dodecan-1-ol as organic solution, 1.5 M HNO3 as acceptor solution, 60 min extraction time, and 800 rpm stirring speed in the sample. Loss of organic solution into the sample during extraction was evaluated and revealed its dependence on stirring rate and extraction time. Under optimum conditions samples containing Cd 0.09-0.90 nM were pre-concentrated 65 times. GF-AAS was used for metal quantification with a limit of detection of 0.04 nM. Accuracy was successfully evaluated measuring Cd in a seawater certified reference material BCR-403.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Água do Mar / Cádmio / Líquidos Iônicos / Microextração em Fase Líquida Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Água do Mar / Cádmio / Líquidos Iônicos / Microextração em Fase Líquida Idioma: En Ano de publicação: 2018 Tipo de documento: Article