Your browser doesn't support javascript.
loading
An Absorbable Hydrogel Spray Reduces Postoperative Mediastinal Adhesions After Congenital Heart Surgery.
Hasaniya, Nahidh; Razzouk, Anees; Newcombe, Jennifer; Hassneiah, Dana; Heimes, Jessica; Gysbers, Joshua; Martens, Timothy; Bailey, Leonard.
Afiliação
  • Hasaniya N; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California. Electronic address: nhasaniya@llu.edu.
  • Razzouk A; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Newcombe J; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Hassneiah D; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Heimes J; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Gysbers J; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Martens T; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
  • Bailey L; Department of Cardiovascular and Thoracic Surgery, Loma Linda University Children's Hospital, Loma Linda, California.
Ann Thorac Surg ; 105(3): 837-842, 2018 03.
Article em En | MEDLINE | ID: mdl-29145993
ABSTRACT

BACKGROUND:

Adhesions encountered during reoperative cardiac surgery can prolong operative time and increase operative risk. The purpose of this clinical study was to investigate the antiadhesion property of a synthetic bioabsorbable polymer spray after cardiac reoperations in infants.

METHODS:

A prospective randomized double-blinded study was designed. Forty infants requiring staged cardiac operations were randomly allocated to a study group (n = 20) or a control group (n = 20). The appropriate volume of the polymer was sprayed onto the mediastinal surfaces before chest closure after the first surgical procedure in the study group. At reoperation, adhesions were evaluated by a blinded investigator following a 5-grade scoring system. Five predetermined anatomic areas were scored. Incision to extracorporeal circulation time was also analyzed.

RESULTS:

In all, 40 subjects were enrolled into the study. Four babies died before the second operation. Three others were missed for reevaluation. The control group (n = 16) had longer incision to extracorporeal circulation time (38 ± 10 minutes) than the study group (n = 17; 23 ± 6 minutes; p < 0.001). The control subjects had significantly more severe adhesions than the study group at all five mediastinal areas (1) retrosternal (p < 0.001); (2) base of the heart (large vessels [p < 0.05]); (3) right side (p < 0.01); (4) left side (p < 0.02); and (5) diaphragmatic side of the mediastinum (p < 0.001).

CONCLUSIONS:

The use of synthetic bioabsorbable polymer sealant spray at the end of primary pediatric cardiac surgery reduces the intensity of mediastinal adhesions and the reentry time in infants undergoing repeat median sternotomy.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Complicações Pós-Operatórias / Esternotomia / Cardiopatias Congênitas / Doenças do Mediastino Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Complicações Pós-Operatórias / Esternotomia / Cardiopatias Congênitas / Doenças do Mediastino Idioma: En Ano de publicação: 2018 Tipo de documento: Article