Your browser doesn't support javascript.
loading
Improved Assessment of Bolus Clearance in Patients With Achalasia Using High-Resolution Impedance Manometry.
Carlson, Dustin A; Beveridge, Claire A; Lin, Zhiyue; Balla, Michelle; Gregory, Dyanna; Tye, Michael; Ritter, Katherine; Kahrilas, Peter J; Pandolfino, John E.
Afiliação
  • Carlson DA; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois. Electronic address: dustin-carlson@northwestern.edu.
  • Beveridge CA; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Lin Z; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Balla M; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Gregory D; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Tye M; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Ritter K; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Kahrilas PJ; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
  • Pandolfino JE; Division of Gastroenterology and Hepatology, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
Clin Gastroenterol Hepatol ; 16(5): 672-680.e1, 2018 05.
Article em En | MEDLINE | ID: mdl-29155168
ABSTRACT
BACKGROUND &

AIMS:

Esophageal retention is typically evaluated by timed-barium esophagram in patients treated for achalasia. Esophageal bolus clearance can also be evaluated using high-resolution impedance manometry. We evaluated the associations of conventional and novel high-resolution impedance manometry metrics, esophagram, and patient-reported outcomes (PROs) in achalasia.

METHODS:

We performed a prospective study of 70 patients with achalasia (age, 20-81 y; 30 women) treated by pneumatic dilation or myotomy who underwent follow-up evaluations from April 2013 through December 2015 (median, 12 mo after treatment; range, 3-183 mo). Patients were assessed using timed-barium esophagrams, high-resolution impedance manometry, and PROs, determined from Eckardt scores (the primary outcome) and the brief esophageal dysphagia questionnaire. Barium column height was measured from esophagrams taken 5 minutes after ingestion of barium (200 mL). Impedance-manometry was analyzed for bolus transit (dichotomized) and with a customized MATLAB program (The MathWorks, Inc, Natick, MA) to calculate the esophageal impedance integral (EII) ratio.

RESULTS:

Optimal cut points to identify a good PRO (defined as Eckardt score of ≤3) were esophagram barium column height of 3 cm (identified patients with a good PRO with 63% sensitivity and 75% specificity) and an EII ratio of 0.41 (identified patients with a good PRO with 83% sensitivity and 75% specificity). Complete bolus transit identified patients with a good PRO with 28% sensitivity and 75% specificity. Of the 25 patients who met these cut points for both esophagram barium column height and EII ratio, 23 (92%) had a good PRO. Of the 17 patients who met neither cut point, 14 (82%) had a poor PRO (Eckardt score above 3).

CONCLUSIONS:

In a prospective study of 70 patients with achalasia, we found EII ratio identified patients with good PROs with higher levels of sensitivity (same specificity) than timed-barium esophagram or impedance-manometry bolus transit assessments. The EII ratio should be added to achalasia outcome evaluations that involve high-resolution impedance manometry as an independent measure and to complement timed-barium esophagram.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bário / Acalasia Esofágica / Impedância Elétrica / Testes Diagnósticos de Rotina / Manometria Idioma: En Ano de publicação: 2018 Tipo de documento: Article