Salting-out assisted liquid-liquid extraction coupled with hydrophilic interaction chromatography for the determination of biguanides in biological and environmental samples.
Alshishani, Anas; Salhimi, Salizawati Muhamad; Saad, Bahruddin.
Afiliação
  • Alshishani A; School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia. Electronic address: anasshishani@gmail.com.
  • Salhimi SM; School of Pharmaceutical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia.
  • Saad B; School of Chemical Sciences, Universiti Sains Malaysia, 11800 Penang, Malaysia; Fundamental & Applied Science Department, Universiti Technologi PETRONAS, 32601 Seri Iskandar, Perak Darul Ridzuan, Malaysia.
Article em En | MEDLINE | ID: mdl-29241085
ABSTRACT
A new salting-out assisted liquid-liquid extraction (SALLE) sample preparation method for the determination of the polar anti-diabetic biguanide drugs (metformin, buformin and phenformin) in blood plasma, urine and lake water samples were developed. The SALLE was performed by mixing samples (plasma (0.2mL), urine or lake water (1.0mL)) with acetonitrile (0.4mL for plasma, 0.5mL for urine or lake water), sodium hydroxide powder was then added for the phase separation. The effects of type of salting-out reagent, type of extraction solvent, volumes of acetonitrile and sample, amount of sodium hydroxide, vortexing and centrifugation times on the extraction efficiency were investigated. The upper layer, containing the biguanides, was directly injected into a HPLC unit using ZIC-HILIC column (150mm×2.1mm×3.5µm) and was detected at 236nm. The method was validated and calibration curves were linear with r2>0.99 over the range of 20-2000µgL-1 for plasma and 5-2000µgL-1 for urine and lake water samples. The limits of detection were in the range (3.8-5.6)µgL-1, (0.8-1.5)µgL-1 and (0.3-0.8)µgL-1 for plasma, urine and lake water, respectively. The accuracies in the three matrices were within 87.3-103%, 87.4-109%, 82.2-109% of the nominal concentration for metformin, buformin and phenformin, respectively. The relative standard deviation for inter- and intra -day precision were in the range of 1.0-17% for all analytes in the three matrices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Biguanidas / Cromatografia Líquida de Alta Pressão / Extração Líquido-Líquido Idioma: En Ano de publicação: 2018 Tipo de documento: Article