Your browser doesn't support javascript.
loading
Small-angle X-ray scattering tensor tomography: model of the three-dimensional reciprocal-space map, reconstruction algorithm and angular sampling requirements.
Liebi, Marianne; Georgiadis, Marios; Kohlbrecher, Joachim; Holler, Mirko; Raabe, Jörg; Usov, Ivan; Menzel, Andreas; Schneider, Philipp; Bunk, Oliver; Guizar-Sicairos, Manuel.
Afiliação
  • Liebi M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Georgiadis M; Institute for Biomedical Engineering, ETH and University Zurich, 8093 Zurich, Switzerland.
  • Kohlbrecher J; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Holler M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Raabe J; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Usov I; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Menzel A; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Schneider P; Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, England.
  • Bunk O; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Guizar-Sicairos M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
Acta Crystallogr A Found Adv ; 74(Pt 1): 12-24, 2018 Jan 01.
Article em En | MEDLINE | ID: mdl-29269594
ABSTRACT
Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Difração de Raios X / Osso e Ossos / Algoritmos / Tomografia Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Difração de Raios X / Osso e Ossos / Algoritmos / Tomografia Idioma: En Ano de publicação: 2018 Tipo de documento: Article