Your browser doesn't support javascript.
loading
B1-control receive array coil (B-RAC) for reducing B1+ inhomogeneity in abdominal imaging at 3T-MRI.
Kaneko, Yukio; Soutome, Yoshihisa; Habara, Hideta; Bito, Yoshitaka; Ochi, Hisaaki.
Afiliação
  • Kaneko Y; Research and Development Group, Hitachi Ltd., Tokyo, Japan. Electronic address: yukio.kaneko.zy@hitachi.com.
  • Soutome Y; Research and Development Group, Hitachi Ltd., Tokyo, Japan.
  • Habara H; Healthcare Business Unit, Hitachi Ltd., Tokyo, Japan.
  • Bito Y; Healthcare Business Unit, Hitachi Ltd., Tokyo, Japan.
  • Ochi H; Research and Development Group, Hitachi Ltd., Tokyo, Japan.
J Magn Reson ; 287: 25-32, 2018 02.
Article em En | MEDLINE | ID: mdl-29276996
ABSTRACT
B1+ inhomogeneity in the human body increases as the nuclear magnetic resonance (NMR) frequency increases. Various methods have thus been developed to reduce B1+ inhomogeneity, such as a dielectric pad, a coupling coil, parallel transmit, and radio-frequency (RF) shimming. However, B1+ inhomogeneity still remains in some cases of abdominal imaging. In this study, we developed a B1-control receive array coil (B-RAC). Unlike the conventional receive array coil, B-RAC reduces B1+ inhomogeneity by using additional PIN diodes to generate the inductive loop during the RF transmit period. The inductive loop can generate dense and sparse regions of the magnetic flux, which can be used to compensate for B1+ inhomogeneity. First, B-RAC is modeled in the numerical simulation, and the spatial distributions of B1+ in a phantom and a human model were analyzed. Next, we fabricated a 12-channel B-RAC and measured receive sensitivity and B1+ maps in a 3T-MRI experiment. It was demonstrated that B-RAC can reduce B1+ inhomogeneity in the phantom and human model without increasing the maximum local specific absorption rate (SAR) in the body. B-RAC was also found to have almost the same the receive sensitivity as the conventional receive coil. Using RF shimming combined with B-RAC was revealed to more effectively reduce B1+ inhomogeneity than using only RF shimming. Therefore, B-RAC can reduce B1+ inhomogeneity while maintaining the receive sensitivity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Abdome Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Abdome Idioma: En Ano de publicação: 2018 Tipo de documento: Article