Your browser doesn't support javascript.
loading
Comparison of respiratory system impedance in asthma and COPD: A prospective observational study.
Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi.
Afiliação
  • Kamada T; Department of Respiratory Medicine, Kobe City Medical Center West Hospital, Kobe, Japan.
  • Kaneko M; Department of Respiratory Medicine, Kobe City Medical Center West Hospital, Kobe, Japan.
  • Tomioka H; Department of Respiratory Medicine, Kobe City Medical Center West Hospital, Kobe, Japan.
Respirology ; 23(5): 478-484, 2018 May.
Article em En | MEDLINE | ID: mdl-29341360
BACKGROUND AND OBJECTIVE: A single assessment of within-breath variations of respiratory system reactance (Xrs) at 5 Hz (ΔX5) measured by the forced oscillation technique (FOT) has been reported to be useful for the detection of pathophysiological changes in chronic obstructive pulmonary disease (COPD) and asthma. We examined longitudinal changes in respiratory system resistance (Rrs) and Xrs during tidal breathing between stable asthma and COPD patients in order to clarify the features of changes of respiratory system impedance and airflow limitation for these conditions. METHODS: Between April 2013 and September 2013, outpatients with a COPD or asthma diagnosis were recruited. We examined forced expiratory volume in 1 s (FEV1 ) and FOT every 6 months until September 2015. Annual changes were estimated from the linear regression curve slope. RESULTS: We included 57 and 93 subjects with COPD and asthma, respectively. The median follow-up period was 26 months (range: 24-29 months). Within-breath analysis showed that the difference between mean Rrs at 5 Hz and 20 Hz was significantly lower, and ΔX5 more negative, in COPD than in asthma patients. With regard to annual changes, only ΔX5 was significantly different, more negative, in COPD than in asthma patients. Comparing between COPD subjects of Global Initiative Chronic Obstructive Lung Disease (GOLD) stage I/II and those with asthma, there were no significant differences in respiratory system impedance at enrolment, while annual change in ΔX5 was significantly more negative in mild COPD than in asthma patients. CONCLUSION: ΔX5 may be useful for long-term assessment of airflow limitation in COPD.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Asma / Resistência das Vias Respiratórias / Doença Pulmonar Obstrutiva Crônica Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Asma / Resistência das Vias Respiratórias / Doença Pulmonar Obstrutiva Crônica Idioma: En Ano de publicação: 2018 Tipo de documento: Article