Your browser doesn't support javascript.
loading
Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study.
Zeng, Yang; Dabay, Michelle; George, Virginia; Seetharaman, Shalini; de Arruda Indig, Monika; Graminske, Sharon; Kimpel, Nicole; Schmidt, Anna; Boerner, Amanda; Paradiso, Sarai; Delman, Tatyana; Li, Yunyao; Litvak, Viktoriya; Oreizy, Farzad; Chen, Angela; Saleminik, Maryam; Mosqueda, Fred; Lin, Anna; Judge, Kevin.
Afiliação
  • Zeng Y; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Dabay M; American Red Cross Holland Laboratory, Transfusion Innovation Department, Rockville, Maryland 20855.
  • George V; American Red Cross Holland Laboratory, Transfusion Innovation Department, Rockville, Maryland 20855.
  • Seetharaman S; American Red Cross Holland Laboratory, Transfusion Innovation Department, Rockville, Maryland 20855.
  • de Arruda Indig M; Clinical Trial and Cellular Therapy Services, BloodCenter of Wisconsin, Milwaukee, Wisconsin 53233.
  • Graminske S; Clinical Trial and Cellular Therapy Services, BloodCenter of Wisconsin, Milwaukee, Wisconsin 53233.
  • Kimpel N; Clinical Trial and Cellular Therapy Services, BloodCenter of Wisconsin, Milwaukee, Wisconsin 53233.
  • Schmidt A; Clinical Trial and Cellular Therapy Services, BloodCenter of Wisconsin, Milwaukee, Wisconsin 53233.
  • Boerner A; Clinical Trial and Cellular Therapy Services, BloodCenter of Wisconsin, Milwaukee, Wisconsin 53233.
  • Paradiso S; New York Blood Center, Clinical Laboratories, Long Island City, New York 11101.
  • Delman T; New York Blood Center, Clinical Laboratories, Long Island City, New York 11101.
  • Li Y; New York Blood Center, Clinical Laboratories, Long Island City, New York 11101.
  • Litvak V; New York Blood Center, Clinical Laboratories, Long Island City, New York 11101.
  • Oreizy F; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Chen A; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Saleminik M; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Mosqueda F; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Lin A; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
  • Judge K; BD Life Sciences, Medical Affairs and Corporate Clinical Development, San Jose, California 95131.
Cytometry A ; 93(4): 420-426, 2018 04.
Article em En | MEDLINE | ID: mdl-29345745
ABSTRACT
The BD FACSVia™ System features novel designs in hardware, software, and instrument QC. We compared the performance of the BD FACSVia System using the BD Leucocount™ kit with the BD FACSCalibur™ flow cytometer. Leucoreduced platelet (PLT, n = 252) and red blood cell (RBC, n = 278) specimens were enrolled at four sites. Each specimen was stained in four tubes using the BD Leucocount kit reagents and acquired on the two systems. BD Leucocount Control cells (high and low) were used to evaluate the inter-site reproducibility on the BD FACSVia System at three sites over 20 days. Deming regression and Bland-Altman analysis were performed to determine the WBC absolute counts on the BD FACSVia System vs. the BD FACSCalibur system. Assay accuracy for the range of 0-350 WBCs/µl was adequate. For samples with <25 WBCs/µl, the bias with 95% limits of agreement was 0.136 (-1.897 to 2.169) WBC/µl for PLTs (n = 184) and 0.170 (-2.025 to 2.365) WBC/µl for RBCs (n = 193). For inter-site reproducibility, the CV% was 6.46% (upper 95% CI 7.16%) for the PLT high control and 9.49% (10.52%) for the PLT low control. The CV% was 7.51% (8.32%) for the RBC high control and 10.76% (11.92%) for the RBC low control. The BD FACSVia System reported equivalent results of WBC absolute counts for leucoreduced PLT and RBC samples compared to the BD FACSCalibur system. The inter-laboratory reproducibility of the BD FACSVia System met study specifications. © 2018 The Authors. Cytometry Part A Published by Wiley Periodicals, Inc. on behalf of ISAC.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eritrócitos / Citometria de Fluxo / Leucócitos Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eritrócitos / Citometria de Fluxo / Leucócitos Idioma: En Ano de publicação: 2018 Tipo de documento: Article