Comparison of Corneal Tomography: Repeatability, Precision, Misalignment, Mean Elevation, and Mean Pachymetry.
Schröder, Simon; Mäurer, Stephanie; Eppig, Timo; Seitz, Berthold; Rubly, Kathrin; Langenbucher, Achim.
Afiliação
  • Schröder S; a Institute of Experimental Ophthalmology , Saarland University , Homburg/Saar , Germany.
  • Mäurer S; a Institute of Experimental Ophthalmology , Saarland University , Homburg/Saar , Germany.
  • Eppig T; a Institute of Experimental Ophthalmology , Saarland University , Homburg/Saar , Germany.
  • Seitz B; b Department of Ophthalmology , Saarland University Medical Center , Homburg/Saar , Germany.
  • Rubly K; a Institute of Experimental Ophthalmology , Saarland University , Homburg/Saar , Germany.
  • Langenbucher A; a Institute of Experimental Ophthalmology , Saarland University , Homburg/Saar , Germany.
Curr Eye Res ; 43(6): 709-716, 2018 06.
Article em En | MEDLINE | ID: mdl-29482368
PURPOSE: To compare corneal tomography and its statistical uncertainty for measurements obtained by three clinically used corneal tomographers: A Scheimpflug camera (Pentacam HR), a swept source optical coherence tomography system (CASIA SS-1000), and Placido ring imaging (TMS-5). MATERIAL AND METHODS: Repeated measurements with all three devices on 34 normal eyes were used to estimate the repeatability, precision, and mean values of corneal elevation and pachymetry within 8 mm diameter. The repeatability (standard deviation) was calculated for each data point of the corneal elevation data-maps of anterior and posterior cornea as well as for the pachymetry data-maps. Uncertainty on the position of the eye at each measurement might contribute to the differences between elevation data-maps. To take this into account, we defined the precision as the standard deviation for the elevation data-maps of anterior and posterior cornea after correction of misalignment-effects (rotation, translation). The mean elevation and pachymetry data-maps were fitted with Zernike polynomials for interdevice-comparison. RESULTS: Pentacam HR offered the best repeatability and precision for the anterior corneal elevation (<3 and <1.6 µm, respectively). CASIA SS-1000 offered good repeatability and precision with high resolution for posterior corneal elevation, and the best repeatability for pachymetry (<3 µm). TMS-5 measured anterior elevation with similar repeatability to CASIA SS-1000 (<6 µm). The data-maps of the three tomographers could not be used interchangeably. The largest differences were observed for pachymetry and posterior corneal elevation data-maps. CONCLUSIONS: Misalignment limited the repeatability of TMS-5 and Pentacam HR, but had little influence on the repeatability of CASIA SS-1000.