Your browser doesn't support javascript.
loading
Sequential high intensity focused ultrasound (HIFU) ablation in the treatment of benign multinodular goitre: an observational retrospective study.
Lang, Brian H H; Woo, Yu-Cho; Chiu, Keith Wan-Hang.
Afiliação
  • Lang BHH; Department of Surgery, The University of Hong Kong Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR, China. blang@hku.hk.
  • Woo YC; Department of Medicine, The University of Hong Kong Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR, China.
  • Chiu KW; Department of Radiology, The University of Hong Kong Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR, China.
Eur Radiol ; 28(8): 3237-3244, 2018 Aug.
Article em En | MEDLINE | ID: mdl-29556769
ABSTRACT

OBJECTIVES:

Assessing the efficacy and safety of sequential high-intensity focused ultrasound (HIFU) ablation in a multinodular goitre (MNG) by comparing them with single HIFU ablation.

METHODS:

One hundred and four (84.6%) patients underwent single ablation of a single nodule (group I), while 19 (15.4%) underwent sequential ablation of two relatively-dominant nodules in a MNG (group II). Extent of shrinkage per nodule [by volume reduction ratio (VRR)], pain scores (by 0-10 visual analogue scale) during and after ablation, and rate of vocal cord palsy (VCP), skin burn and nausea/vomiting were compared between the two groups.

RESULTS:

All 19 (100%) sequential ablations completed successfully. The 3- and 6-month VRR of each nodule were comparable between the two groups (p > 0.05) and in group II, the 3- and 6-month VRR between the first and second nodules were comparable (p = 0.710 and p = 0.548, respectively). Pain score was significantly higher in group II in the morning after ablation (2.29 vs 1.15, p = 0.047) and nausea/vomiting occurred significantly more frequently in group II (15.8% vs 0.0%, p = 0.012). However, VCP and skin burn were comparable (p > 0.05).

CONCLUSIONS:

Sequential ablation had comparable efficacy and safety as single ablation. However, patients undergoing sequential ablation are at higher likelihood of pain in the following morning and nausea/vomiting after ablation. KEY POINTS • Sequential HIFU ablation is well-tolerated in patients with two dominant thyroid nodules • More pain is experienced in the morning following sequential HIFU ablation • More nausea/vomiting is experienced following sequential HIFU ablation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Ablação por Ultrassom Focalizado de Alta Intensidade / Bócio Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Ablação por Ultrassom Focalizado de Alta Intensidade / Bócio Idioma: En Ano de publicação: 2018 Tipo de documento: Article