Your browser doesn't support javascript.
loading
Dianion diagnostics in DESIREE: High-sensitivity detection of Cn2- from a sputter ion source.
Chartkunchand, K C; Stockett, M H; Anderson, E K; Eklund, G; Kristiansson, M K; Kaminska, M; de Ruette, N; Blom, M; Björkhage, M; Källberg, A; Löfgren, P; Reinhed, P; Rosén, S; Simonsson, A; Zettergren, H; Schmidt, H T; Cederquist, H.
Afiliação
  • Chartkunchand KC; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Stockett MH; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Anderson EK; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Eklund G; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Kristiansson MK; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Kaminska M; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • de Ruette N; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Blom M; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Björkhage M; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Källberg A; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Löfgren P; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Reinhed P; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Rosén S; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Simonsson A; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Zettergren H; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Schmidt HT; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
  • Cederquist H; Department of Physics, Stockholm University, AlbaNova, SE-106 91 Stockholm, Sweden.
Rev Sci Instrum ; 89(3): 033112, 2018 Mar.
Article em En | MEDLINE | ID: mdl-29604753
ABSTRACT
A sputter ion source with a solid graphite target has been used to produce dianions with a focus on carbon cluster dianions, Cn2-, with n = 7-24. Singly and doubly charged anions from the source were accelerated together to kinetic energies of 10 keV per atomic unit of charge and injected into one of the cryogenic (13 K) ion-beam storage rings of the Double ElectroStatic Ion Ring Experiment facility at Stockholm University. Spontaneous decay of internally hot Cn2- dianions injected into the ring yielded Cn- anions with kinetic energies of 20 keV, which were counted with a microchannel plate detector. Mass spectra produced by scanning the magnetic field of a 90° analyzing magnet on the ion injection line reflect the production of internally hot C72- - C242- dianions with lifetimes in the range of tens of microseconds to milliseconds. In spite of the high sensitivity of this method, no conclusive evidence of C62- was found while there was a clear C72- signal with the expected isotopic distribution. This is consistent with earlier experimental studies and with theoretical predictions. An upper limit is deduced for a C62- signal that is two orders-of-magnitude smaller than that for C72-. In addition, CnO2- and CnCu2- dianions were detected.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article