Your browser doesn't support javascript.
loading
Application of wavelet analysis to detect dysfunction in cerebral blood flow autoregulation during experimental hyperhomocysteinaemia.
Aleksandrin, Valery V; Ivanov, Alexander V; Virus, Edward D; Bulgakova, Polina O; Kubatiev, Aslan A.
Afiliação
  • Aleksandrin VV; Department of Molecular and Cell Pathophysiology, Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology", Moscow, Russia. aleksandrin-54@mail.ru.
  • Ivanov AV; Department of Molecular and Cell Pathophysiology, Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology", Moscow, Russia.
  • Virus ED; Department of Molecular and Cell Pathophysiology, Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology", Moscow, Russia.
  • Bulgakova PO; Department of Molecular and Cell Pathophysiology, Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology", Moscow, Russia.
  • Kubatiev AA; Department of Molecular and Cell Pathophysiology, Federal State Budgetary Scientific Institution "Institute of General Pathology and Pathophysiology", Moscow, Russia.
Lasers Med Sci ; 33(6): 1327-1333, 2018 Aug.
Article em En | MEDLINE | ID: mdl-29611066
ABSTRACT
The purpose of the present study was to investigate the use of laser Doppler flowmetry (LDF) signals coupled with spectral wavelet analysis to detect endothelial link dysfunction in the autoregulation of cerebral blood flow in the setting of hyperhomocysteinaemia (HHcy). Fifty-one rats were assigned to three groups (intact, control, and HHcy) according to the results of biochemical assays of homocysteine level in blood plasma. LDF signals on the rat brain were recorded by LAKK-02 device to measure the microcirculatory blood flow. The laser operating wavelength and output power density were1064 nm and 0.051 W/mm2, respectively. A Morlet mother wavelet transform was applied to the measured 8-min LDF signals, and periodic oscillations with five frequency intervals were identified (0.01-0.04 Hz, 0.04-0.15 Hz, 0.15-0.4 Hz, 0.4-2 Hz, and 2-5 Hz) corresponding to endothelial, neurogenic, myogenic, respiratory, and cardiac origins, respectively. In initial state, the amplitude of the oscillations decreased by 38% (P < 0.05) in the endothelial range in HHcy rats than in control rats. Cerebral autoregulation was challenged by hemorrhagic hypotension. The lower limit of autoregulation raised in a rat model of chronic HHcy (71.5 ± 0.7 mmHg in HHcy vs. 62.3 ± 0.5 mmHg in control). The data obtained indicate that the laser Doppler method and wavelet analysis may be successfully applied to detect the dysfunction of the endothelial link in cerebral vessel tone and to reveal the pathological shift of lower limit of autoregulation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Cerebrovascular / Hiper-Homocisteinemia / Análise de Ondaletas / Homeostase Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Cerebrovascular / Hiper-Homocisteinemia / Análise de Ondaletas / Homeostase Idioma: En Ano de publicação: 2018 Tipo de documento: Article