Your browser doesn't support javascript.
loading
Air-splinting Maneuver During Flexible Bronchoscopy: A Cross-sectional Study.
Magazine, Rahul; Chogtu, Bharti.
Afiliação
  • Magazine R; Departments of Pulmonary Medicine.
  • Chogtu B; Pharmacology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.
J Bronchology Interv Pulmonol ; 25(4): 315-321, 2018 Oct.
Article em En | MEDLINE | ID: mdl-29659421
ABSTRACT

BACKGROUND:

Magazine's maneuver was developed for ease of insertion of the flexible bronchoscope, on encountering a closed lumen at the nasopharynx-oropharynx junction. The purposes of this study were to find the frequency of occurrence of such luminal closures and to compare the efficacy of Magazine's maneuver, with other variations of the maneuver, in improving visualization of the upper airway. MATERIALS AND

METHODS:

Patients aged 18 years and above who were undergoing flexible bronchoscopy were included, and their demographic and clinical data were noted. The bronchoscope was inserted using the transnasal approach, and, at the junction of nasopharynx with oropharynx, the patency of the lumen between the soft palate and the posterior pharyngeal wall was recorded. The subjects were instructed to perform 4 variations of the maneuver. Observations at each variation were recorded as lumen open or closed; if the lumen was open, the size was noted as small or large and whether it closed during expiration.

RESULTS:

Among 443 subjects, obstruction at the nasopharynx-oropharynx junction was observed, at baseline, in 105 (23.7%); whereas 338 (76.3%) had an open lumen. An open lumen was observed during nose and mouth breathing in 294 (66.4%) subjects, and, when head-tilt chin-lift was added to it, it was observed in 303 (68.4%). During Magazine's maneuver the lumen remained open in all 443 (100%) subjects. Half of the subjects (n=8) with body mass index >30 and one-third (n=29) above 65 years of age had luminal closure at baseline.

CONCLUSION:

Magazine's maneuver opens up the obstruction at the nasopharynx-oropharynx junction, whereas mouth and nose breathing mostly fails to do so. Adding head-tilt chin-lift to either of the 2 breathing techniques does not provide any additional benefit.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sistema Respiratório / Broncoscopia / Obstrução das Vias Respiratórias / Tecnologia de Fibra Óptica Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sistema Respiratório / Broncoscopia / Obstrução das Vias Respiratórias / Tecnologia de Fibra Óptica Idioma: En Ano de publicação: 2018 Tipo de documento: Article