Your browser doesn't support javascript.
loading
Quantitation of Perfused Lung Volume Using Hybrid SPECT/CT Allows Refining the Assessment of Lung Perfusion and Estimating Disease Extent in Chronic Thromboembolic Pulmonary Hypertension.
Clin Nucl Med ; 43(6): e170-e177, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29688945
ABSTRACT

BACKGROUND:

We evaluated the feasibility of perfusion SPECT/CT for providing quantitative data for estimation of perfusion defect extent in chronic thromboembolic pulmonary hypertension (CTEPH).

METHODS:

Thirty patients with CTEPH underwent Tc-human serum albumin lung perfusion SPECT/CT. Perfusion defects were quantified using 3 different

methods:

(1) visual, semiquantitative scoring of perfusion defect extent in each lung segment, (2) threshold-based segmentation of perfused lung volumes, and (3) threshold-based segmentation of perfused lung volumes divided by segmented lung volumes at CT (perfusion index). Imaging findings were correlated with right-sided heart catheterization results and N-terminal pro-B-type natriuretic peptide. Receiver operating characteristic analysis was performed to identify SPECT thresholds for mean pulmonary arterial pressure (PAPm) greater than 50 mm Hg.

RESULTS:

Assessment of lung perfusion provided similar results using all 3 methods. The perfusion defect score correlated with PAPm (rs = 0.60, P = 0.0005) and was associated with serum levels of N-terminal pro-B-type natriuretic peptide (rs = 0.37, P = 0.04). Perfused lung volume (40% threshold, rs = -0.48, P = 0.007) and perfusion index (40% threshold, rs = -0.50, P = 0.005) decreased as PAPm increased. Receiver operating characteristic analysis showed that perfusion defect score (sensitivity, 88%; specificity, 77%; area under the curve [AUC] = 0.89, P = 0.001), perfused lung volume (sensitivity, 88%; specificity, 64%; AUC = 0.80, P = 0.01), and perfusion index (sensitivity, 88%; specificity, 64%; AUC = 0.82, P = 0.009) could identify patients with PAPm of greater than 50 mm Hg.

CONCLUSIONS:

Quantitative analysis of perfusion defects at SPECT is feasible, provides a measure of disease severity, and correlates with established clinical parameters. Quantitation of perfusion SPECT may refine the diagnostic approach in CTEPH providing a quantitative imaging biomarker, for example, for therapy monitoring.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único / Hipertensão Pulmonar Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único / Hipertensão Pulmonar Idioma: En Ano de publicação: 2018 Tipo de documento: Article