Your browser doesn't support javascript.
loading
Viscoelasticity and structure of blood clots generated in-vitro by rheometry: A comparison between human, horse, rat, and camel.
Dibiasi, Christoph; Plewka, Jacek; Ploszczanski, Leon; Glanz, Veronika; Lichtenegger, Helga; Windberger, Ursula.
Afiliação
  • Dibiasi C; Department of Biomedical Research, Decentralized Biomedical Facilities, Medical University of Vienna, Austria.
  • Plewka J; Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria.
  • Ploszczanski L; Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria.
  • Glanz V; Department of Biomedical Research, Decentralized Biomedical Facilities, Medical University of Vienna, Austria.
  • Lichtenegger H; Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria.
  • Windberger U; Department of Biomedical Research, Decentralized Biomedical Facilities, Medical University of Vienna, Austria.
Clin Hemorheol Microcirc ; 69(4): 515-531, 2018.
Article em En | MEDLINE | ID: mdl-29710696
ABSTRACT

BACKGROUND:

Although the coagulation system is evolutionary well preserved, profound species differences exist in viscoelastic as well as in common laboratory tests of coagulation.

OBJECTIVE:

Evaluating differences in clot formation and material characterisation of clots of four mammalian species on macro-, micro- and nanoscales by the means of rheometry, scanning electron microscopy (SEM) and small angle x-ray scattering (SAXS).

METHODS:

Blood samples were collected from healthy human volunteers, laboratory rats (HL/LE inbred strain), warmblood horses and dromedary camels. Clot formation was observed by oscillating shear rheometry until plateau formation of the shear storage modulus G', at which point selected clots were prepared for scanning electron microscopy. SEM images were analysed for fibre diameter and fractal dimension. Additionally, scattering profiles for plasma and whole blood samples were obtained with SAXS.

RESULTS:

Viscoelasticity of clots showed great interspecies variation clots of rats and horses exhibited shorter clotting times and higher G' plateau values, when compared to human clots. Camel clots showed unique clotting characteristics with no G' plateau formation in the timeframe observed. Less differentiating features were found with SEM and SAXS, although the rat fibre network appears to be more convoluted and dense, which resulted in a higher fractal dimension.

CONCLUSION:

Clotting kinetic differs between the species, which is not only of clinical interest, but could also be an important finding for animal models of blood coagulation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombose / Coagulação Sanguínea / Testes de Coagulação Sanguínea Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombose / Coagulação Sanguínea / Testes de Coagulação Sanguínea Idioma: En Ano de publicação: 2018 Tipo de documento: Article