Your browser doesn't support javascript.
loading
Cell Fragmentation and Permeabilization by a 1 ns Pulse Driven Triple-Point Electrode.
Yang, Enbo; Li, Joy; Cho, Michael; Xiao, Shu.
Afiliação
  • Yang E; Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA.
  • Li J; Department of Biomedical Engineering, Cornell University, Ithaca, NY, USA.
  • Cho M; Department of Bioengineering, University of Texas, Arlington, TX, USA.
  • Xiao S; Frank Reidy Research Center for Bioelectrics, Old Dominion University, Norfolk, VA, USA.
Biomed Res Int ; 2018: 4072983, 2018.
Article em En | MEDLINE | ID: mdl-29744357
ABSTRACT
Ultrashort electric pulses (ns-ps) are useful in gaining understanding as to how pulsed electric fields act upon biological cells, but the electric field intensity to induce biological responses is typically higher than longer pulses and therefore a high voltage ultrashort pulse generator is required. To deliver 1 ns pulses with sufficient electric field but at a relatively low voltage, we used a glass-encapsulated tungsten wire triple-point electrode (TPE) at the interface among glass, tungsten wire, and water when it is immersed in water. A high electric field (2 MV/cm) can be created when pulses are applied. However, such a high electric field was found to cause bubble emission and temperature rise in the water near the electrode. They can be attributed to Joule heating near the electrode. Adherent cells on a cover slip treated by the combination of these stimuli showed two major effects (1) cells in a crater (<100 µm from electrode) were fragmented and the debris was blown away. The principal mechanism for the damage is presumed to be shear forces due to bubble collapse; and (2) cells in the periphery of the crater were permeabilized, which was due to the combination of bubble movement and microstreaming as well as pulsed electric fields. These results show that ultrashort electric fields assisted by microbubbles can cause significant cell response and therefore a triple-point electrode is a useful ablation tool for applications that require submillimeter precision.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Membrana Celular / Permeabilidade da Membrana Celular / Campos Eletromagnéticos Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Membrana Celular / Permeabilidade da Membrana Celular / Campos Eletromagnéticos Idioma: En Ano de publicação: 2018 Tipo de documento: Article