Your browser doesn't support javascript.
loading
Elaboration and validation of the method for the quantification of the emetic toxin of Bacillus cereus as described in EN-ISO 18465 - Microbiology of the food chain - Quantitative determination of emetic toxin (cereulide) using LC-MS/MS.
In 't Veld, P H; van der Laak, L F J; van Zon, M; Biesta-Peters, E G.
Afiliação
  • In 't Veld PH; Netherlands Food and Consumer Safety Authority, Division Consumer and Safety, Department of Enforcement Development (NVWA), Catharijnesingel 59, 3511 GG Utrecht, The Netherlands. Electronic address: p.h.intveld@nvwa.nl.
  • van der Laak LFJ; Netherlands Food and Consumer Safety Authority, Division Consumer and Safety, Laboratory for Food and Feed Safety (NVWA), Akkersmaalsbos 2, 6708 WB Wageningen, The Netherlands.
  • van Zon M; Netherlands Food and Consumer Safety Authority, Division Consumer and Safety, Laboratory for Food and Feed Safety (NVWA), Akkersmaalsbos 2, 6708 WB Wageningen, The Netherlands.
  • Biesta-Peters EG; Netherlands Food and Consumer Safety Authority, Division Consumer and Safety, Laboratory for Food and Feed Safety (NVWA), Akkersmaalsbos 2, 6708 WB Wageningen, The Netherlands.
Int J Food Microbiol ; 288: 91-96, 2019 Jan 02.
Article em En | MEDLINE | ID: mdl-29754873
ABSTRACT
A method for the quantification of the Bacillus cereus emetic toxin (cereulide) was developed and validated. The method principle is based on LC-MS as this is the most sensitive and specific method for cereulide. Therefore the study design is different from the microbiological methods validated under this mandate. As the method had to be developed a two stage validation study approach was used. The first stage (pre-study) focussed on the method applicability and the experience of the laboratories with the method. Based on the outcome of the pre-study and comments received during voting at CEN and ISO level a final method was agreed to be used for the second stage the (final) validation of the method. In the final (validation) study samples of cooked rice (both artificially contaminated with cereulide or contaminated with B. cereus for production of cereulide in the rice) and 6 other food matrices (fried rice dish, cream pastry with chocolate, hotdog sausage, mini pancakes, vanilla custard and infant formula) were used. All these samples were spiked by the participating laboratories using standard solutions of cereulide supplied by the organising laboratory. The results of the study indicate that the method is fit for purpose. Repeatability values were obtained of 0.6 µg/kg at low level spike (ca. 5 µg/kg) and 7 to 9.6 µg/kg at high level spike (ca. 75 µg/kg). Reproducibility at low spike level ranged from 0.6 to 0.9 µg/kg and from 8.7 to 14.5 µg/kg at high spike level. Recovery from the spiked samples ranged between 96.5% for mini-pancakes to 99.3% for fries rice dish.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Depsipeptídeos / Espectrometria de Massas em Tandem / Microbiologia de Alimentos Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Depsipeptídeos / Espectrometria de Massas em Tandem / Microbiologia de Alimentos Idioma: En Ano de publicação: 2019 Tipo de documento: Article