PURPOSE:
We evaluated the applicability of the ISNT rule using Bruch's membrane opening minimum rim width (BMO-MRW) in healthy eyes and eyes with normal tension glaucoma (NTG). MATERIALS ANDMETHODS:
In total, 124 healthy eyes and 136 NTG eyes were analyzed. Using 2-dimensional disc photographs, neuroretinal rim (NRR) thickness was measured at the superior, inferior, nasal, and temporal sides of the optic disc. Using spectral domain-optical coherence tomography, BMO-MRW was measured at the same regions. We compared the applicability of the ISNT rule in healthy and NTG eyes between these 2 methods. If the NRR was not clearly distinguished on disc photographs, the eye was classified into the "indistinguishable NRR" group and we only tested applicability of the ISNT rule using BMO-MRW.RESULTS:
The specificity of "violation of the ISNT rule" for the diagnosis of glaucoma was higher when BMO-MRW was used (66.3%) than using disc photographs (42.2%), whereas the sensitivity did not show a significant difference between the 2 methods (91.7% vs. 86.5%). Compared with eyes with distinguishable NRR (179 eyes), eyes with indistinguishable NRR (81 eyes) had higher axial length, more negative refractive error, and higher tilt ratio (P<0.001). The diagnostic ability of "violation of ISNT rule" using BMO-MRW was not significantly different between eyes with indistinguishable NRR and those with distinguishable NRR (P>0.05).CONCLUSIONS:
Application of the ISNT rule using BMO-MRW shows superiority in distinguishing between healthy and glaucomatous optic discs compared with disc photographs. The ISNT rule can be applied using BMO-MRW even when NRR is indistinguishable on disc photographs, such as in myopic tilted discs.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Lâmina Basilar da Corioide
/
Guias de Prática Clínica como Assunto
/
Técnicas de Diagnóstico Oftalmológico
/
Glaucoma de Baixa Tensão
Idioma:
En
Ano de publicação:
2018
Tipo de documento:
Article