Three-way DNA junction based platform for ultra-sensitive fluorometric detection of multiple metal ions as exemplified for Cu(II), Mg(II) and Pb(II).
Yun, Wen; Du, Xiaoqing; Liao, Junsheng; Sang, Ge; Chen, Lin; Li, Ning; Yang, Lizhu.
Afiliação
  • Yun W; Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China.
  • Du X; Institute of Materials, China Academy of Engineering Physics, Mianyang, 621908, Sichuan, China.
  • Liao J; Institute of Materials, China Academy of Engineering Physics, Mianyang, 621908, Sichuan, China.
  • Sang G; Institute of Materials, China Academy of Engineering Physics, Mianyang, 621908, Sichuan, China.
  • Chen L; State Key Laboratory of Environmental Friendly Energy Materials & School of Material Science and Engineering, Southwest University of Science and Technology, Mianyang, 621010, China. chenlin101101@aliyun.com.
  • Li N; Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing, 400067, China. 157020769@qq.com.
  • Yang L; School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China. yanglz3000@aliyun.com.
Mikrochim Acta ; 185(6): 306, 2018 05 20.
Article em En | MEDLINE | ID: mdl-29779060
ABSTRACT
A DNA-based fluorometric method is described for simultaneous determination of multiple metal ions. It is based on recycling cleavage of hairpins by using a three-way DNA junction structure. Three DNA sequences containing a binding region and an enzyme-strand (E-DNA) region are hybridized to form a three-way DNA junction. The enzyme strand regions at the end of the DNA sequence binds to the substrate sequence (S-DNA) at the loop of the hairpin to form typical DNAzyme structures. In the presence of analyte metal ions, the DNAzyme structure thus formed cleaves the loop of hairpins. This is accompanied by a release of fluorescently labeled DNA fragments and by quenching of fluorescence. The detection limits are 35 pM for Cu(II), 2 nM for Mg(II), and 8 pM for Pb(II). This method was successfully applied to the simultaneous determination of these ions in spiked human serum. Graphical abstract Schematic presentation of the recycling cleavage of hairpins by using a three-way DNA junction structure. It causes a release of fluorescently labeled DNA fragments and quenching of fluorescence. It was successfully applied to the simultaneous determination of Cu(II), Mg(II) and Pb(II) in spiked human serum.