Your browser doesn't support javascript.
loading
Evaluation of MALDI-TOF MS for identification of nontuberculous mycobacteria isolated from clinical specimens in mycobacteria growth indicator tube medium.
Genc, Gonca Erkose; Demir, Melda; Yaman, Görkem; Kayar, Begum; Koksal, Fatih; Satana, Dilek.
Afiliação
  • Genc GE; Istanbul University, Istanbul Faculty of Medicine, Department of Medical Microbiology, Istanbul, Turkey.
  • Demir M; Istanbul University, Istanbul Faculty of Medicine, Department of Medical Microbiology, Istanbul, Turkey.
  • Yaman G; Maltepe University, Faculty of Medicine, Department of Medical Microbiology and Duzen Laboratories Group, Department of Tuberculosis, Istanbul, Turkey.
  • Kayar B; Cukurova University, Faculty of Medicine, Department of Medical Microbiology, Adana, Turkey.
  • Koksal F; Cukurova University, Faculty of Medicine, Department of Medical Microbiology, Adana, Turkey.
  • Satana D; Istanbul University, Istanbul Faculty of Medicine, Department of Medical Microbiology, Istanbul, Turkey.
New Microbiol ; 41(3): 214-219, 2018 07.
Article em En | MEDLINE | ID: mdl-29874386
Nowadays, there is a rising worldwide incidence of diseases caused by nontuberculous mycobacteria (NTM) species, especially in immunocompromised patients and those with underlying chronic pulmonary diseases. Recently, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) became a method of choice for the identification of NTM species. The aim of this study was to evaluate MALDI-TOF MS for the identification of NTM isolates compared to the PCR-restriction enzyme analysis (PRA)-hsp65 method. In this study, a total of 152 NTM strains isolated from various clinical specimens were retrospectively analysed. MALDI-TOF MS successfully identified 148 (97.4%) of the 152 NTM isolates but failed to identify four (2.6%) of them. Bruker mycobacteria library gave spectral scores higher than 2.0 for 45 (29.6%) of NTM isolates, between 1.6 and 2.0 for 98 (64.5%) of NTM isolates, and lower than 1.6 for nine (5.9%) NTM isolates. The discordant results between MALDI-TOF MS and PRA-hsp65 analysis were confirmed by sequence analysis. In conclusion, MALDI-TOF MS is a technique capable of performing accurate, rapid, cost-effective, and easy identification of NTM isolates.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Micobactérias não Tuberculosas / Infecções por Mycobacterium não Tuberculosas Idioma: En Ano de publicação: 2018 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Micobactérias não Tuberculosas / Infecções por Mycobacterium não Tuberculosas Idioma: En Ano de publicação: 2018 Tipo de documento: Article